Response time, power, flow (C, b, Cv), pressure range and weight for the blowback valve.

Author
SMC Corporation
Year
undated
Type
Datasheet
Credit
SMC (smcetech.com)
  • solenoid valve
  • pneumatics
  • 3-port

← Back to the Reference Library

SMC V100 Series Direct Operated 3-Port Solenoid Valve — Catalogue

Direct Operated *1 3-Port Solenoid Valve *1 DC type only Power consumption: 0.1 W*2 (Standard type, With power-saving circuit) Coil temperature rise: 1°C (Standard type, With power-saving circuit) Large flow type (Type U) Large flow type (Type A) Standard type Sonic conductance C[dm3/(s·bar)] 0.16 0.076 0.037 Standard Power consumption With power[W] saving circuit — 1 0.35 0.35 — 0.1*2 *2 Refer to page 1 for details. V100 Series CAT.ES11-82C Direct Operated 3-Port Solenoid Valve V100 Series *1 *1 DC type only Rubber Seal Specifications Fluid Ambient and fluid temperatures [°C] Response time (DC) [ms]*1 Air −10 to 50 (No freezing) ON: 5 or less OFF: 4 or less 20*3 Max. operating frequency [Hz] Manual override Non-locking push, Locking slotted Lubrication Not required Mounting position Unrestricted Impact/Vibration resistance [m/s2]*2 150/30 Enclosure Dustproof *1 Based on the JIS B 8419: 2010 dynamic performance test (Standard type: Coil temperature 20°C, at rated voltage, without surge voltage suppressor) *2 Impact resistance: No malfunction occurred when tested with a drop tester in the axial direction and at a right angle to the armature in both an energized and a de-energized state, once in each condition. (Value in the initial state) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz in the axial direction and at a right angle to the armature in both an energized and a de-energized state, once in each condition. (Value in the initial state) *3 Please contact SMC for the large flow type (Type U). Solenoid Specifications V114/V124 Series Electrical entry Coil rated voltage [V] Symbol V114(A,UT) 2 1 3 DC AC 50/60 Hz 2 1 3 Power consumption [W] Apparent power [VA] 24, 12, 6, 5, 3 24 100, 110, 200, 220 — −10 to 10%*1 1 W (With light: 1.1) With power-saving circuit: 0.35*2 [Inrush: 3.2, Holding: 0.35] 100 V 0.78 (With light: 0.81) — — 110 V [115 V] 0.86 (With light: 0.89) [0.94 (With light: 0.97)] — — 200 V 1.18 (With light: 1.22) — — 220 V [230 V] 1.30 (With light: 1.34) [1.42 (With light: 1.46)] — — Surge voltage suppressor Indicator light — Standard: 0.35 (With light: 0.4) With power-saving circuit: 0.1*2 [Inrush: 0.4, Holding: 0.1] DC AC V114UT L plug connector (L), M plug connector (M) Allowable voltage fluctuation V124(A) V114A/V124A Grommet (G)/(H), L plug connector (L), M plug connector (M) Refer to page 12. LED * The 110 VAC and the 115 VAC are interchangeable. The 220 VAC and the 230 VAC are interchangeable as well. *1 The allowable voltage fluctuation is –15% to +5% of the rated voltage for the 115 VAC or the 230 VAC. *1 For the allowable voltage fluctuation for types S, Z, and T (with power-saving circuit), please observe the following ranges because they experience voltage drops due to the internal circuit. Types S and Z 24 VDC: −7% to +10% 12 VDC: −4% to +10% Type T 24 VDC: −8% to +10% 12 VDC: −6% to +10% * Select the DC standard model or the model with power-saving circuit when the valve is to be continuously energized for long periods of time. *2 Refer to page 12 for details. 1 3-Port Solenoid Valve V100 Series Specifications Valve model V114 V114A V114UT V124∗1 V124A∗1 Vacuum specification [MPa]∗4 Operating 4 ∗ Type pressure range Port 1 Port 3 [MPa] N.C. Standard type 0 to 0.7 −100 kPa to 0.6 −100 kPa to 0 N.C. Large flow type (Type A) 0 to 0.7 −100 kPa to 0.6 −100 kPa to 0 0 to 0.6 −100 kPa to 0.5 −100 kPa to 0 N.C. Large flow type (Type U) N.O. Standard type 0 to 0.7 −100 kPa to 0 −100 kPa to 0.6 N.O. Large flow type (Type A) 0 to 0.7 −100 kPa to 0 −100 kPa to 0.6 Type of actuation Valve model 1 → 2 [3 → 2∗3] b 0.11 0.07 0.18 0.35 0.23 C [dm3/(s·bar)] 0.037 0.076 0.16 0.054 0.099 V114 V114A V114UT V124∗1 V124A∗1 Port 1, 3 Port 2 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 Flow rate characteristics Cv 0.008 0.016 0.038 0.015 0.024 Weight [g]∗2 L plug connector Grommet M plug connector Port size V1m4: 13 (27) V1m4A: 16 (30) V1m4: 12 (26) V1m4A: 15 (29) V114UT: 15 (29) 2 → 3 [2 → 1∗3] b 0.35 0.23 0.34 0.11 0.07 C [dm3/(s·bar)] 0.054 0.099 0.15 0.037 0.076 Cv 0.015 0.024 0.041 0.008 0.016 ∗1 For both the V124 and the V124A, pressure from port 3 and exhaust from port 1. ∗2 The values shown in ( ) are for values with sub-plate. ∗3 For the V124(A) ∗4 Please note that, if the difference between the inlet side and the outlet side is extremely low (0.001 MPa or less as a guide), air may not be output or the flow rate may deteriorate excessively due to the quality of the lubricant and air in the solenoid valve (mixing in of the drain, etc.). Construction V114(A, UT) 2 Component Parts 2 1 3 u V124(A) No. 1 2 3 4 5 6 7 8 9 1 3 t o e Description Body Cover Push rod Armature assembly Poppet Return spring Poppet spring Coil assembly Manual override Material Resin Stainless steel Resin Stainless steel, Resin FKM, HNBR Stainless steel Stainless steel — Resin Replacement Parts No. Description 10 Gasket assembly 11 Sub-plate Part no. V100-31-1A V100-74-1 Material Note FKM, Steel Gasket, 2 screws Aluminum die-cast — How to Order Connector Assembly q !0 1 2 3 (P) (A) (R) w y i r !1 For DC: SY100 30 4A For 100 VAC: SY100 30 1A For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A Without lead wire: SY100 30 A (with connector and 2 sockets) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm 2 V100 Series ∗1 How to Order ∗1 DC type only Standard type Base mounted V1 1 4 5 M Sub-plate type, For manifold type S41 Port size Nil: Without sub-plate Type of actuation 1 2 (With gasket and screws) Normally closed Normally open Manual override Coil type Nil T M5: With sub-plate 0.35 W 0.1 W (with power-saving circuit) (24 VDC, 12 VDC only) Nil: Non-locking push * All the types with power-saving circuit are with light and surge voltage suppressor “Z.” Rated voltage For DC 5 6 V S R CE-compliant V V V V V 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted CE-compliant For AC (50/60 Hz) — 100 VAC 1 200 VAC — 2 — 3 110 VAC [115 VAC] — 4 220 VAC [230 VAC] Electrical entry 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC Grommet L plug connector M plug connector G: 300 mm L: With 300 mm lead wire lead wire H: 600 mm lead wire M: With 300 mm MN: Without lead wire lead wire +- +- -+ −+ Light/surge voltage suppressor Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar) With light/surge voltage suppressor (Non-polar) * Only “Z” is available for the models with power-saving circuit. LN: Without lead LO: Without wire connector MO: Without connector -+ * LN and MN types are with 2 sockets. * Refer to page 11 for the different lead wire lengths of L and M plug connectors. * Refer to page 13 for the connector assembly with a dustproof cover for L and M plug connectors. 3 For DC, AC For DC For DC, AC For DC 3-Port Solenoid Valve V100 Series How to Order Large flow type (Type A) Base mounted V1 1 4 A 5 M Sub-plate type, For manifold type S41 Port size Nil: Without sub-plate M5: With sub-plate (With gasket and screws) Type of actuation 1 2 Normally closed Normally open Manual override Nil: Non-locking push Large flow type (Type A) Rated voltage For DC 5 6 V S R CE-compliant V V V V V 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted Electrical entry Grommet 24 V, 12 V, 6 V, 5 V, 3 VDC L plug connector M plug connector G: 300 mm lead wire L: With 300 mm lead wire H: 600 mm lead wire M: With 300 mm lead wire +- MN: Without lead wire +- Light/surge voltage suppressor Nil R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor For DC -+ −+ LO: Without connector LN: Without lead wire MO: Without connector -+ * LN and MN types are with 2 sockets. * Refer to page 11 for the different lead wire lengths of L and M plug connectors. * Refer to page 13 for the connector assembly with a dustproof cover for L and M plug connectors. 4 V100 Series How to Order Large flow type (Type U) Base mounted V1 1 4 U T 5 M Z Sub-plate type, For manifold type S41 Port size Nil: Without sub-plate M5: With sub-plate (With gasket and screws) Type of actuation 1 Normally closed Manual override Nil: Non-locking push Large flow type (Type U) Coil type T 0.35 W (With power-saving circuit) B: Locking slotted Rated voltage For DC 5 CE-compliant V 24 VDC Electrical entry L plug connector 24 VDC M plug connector L: With 300 mm M: With 300 mm MN: Without lead wire lead wire +- lead wire +- Light/surge voltage suppressor Z With light/surge voltage suppressor -+ LN: Without lead LO: Without wire connector MO: Without connector -+ ∗ LN and MN types are with 2 sockets. ∗ Refer to page 11 for the different lead wire lengths of L and M plug connectors. ∗ Refer to page 13 for the connector assembly with a dustproof cover for L and M plug connectors. 5 3-Port Solenoid Valve V100 Series ∗ [ ]: AC < >: Values for the large flow type (Type A, UT) Base Mounted (With sub-plate) Grommet (G), (H): V112 4(A)-m G H mm-M5 13.1 15.5 13 - + 5 (Light/surge voltage suppressor) 3 2 x ø2.6 (Mounting hole) 3 13 5 9.5 M5 x 0.8 (Piping port) L plug connector (L): V112 4(A, UT)-mLmm-M5 (Light/surge voltage suppressor) 5.7 1 5.7 7 2 11.4 25.1 1 (Lead wire length) <33> 10 <32.4> 5.7 G: Approx. 300 H: Approx. 600 30.8 [33] 28.5 [35.5] 5 19 M plug connector (M): V112 4(A, UT)-mMmm-M5 (Light/surge voltage suppressor) 13.1 - + 3 Approx. 300 (Lead wire length) 3 Approx. 300 (Lead wire length) 39.6 [46.6] <43.5> * Other dimensions are the same as those of the grommet type. 25.9 <33.1> 30.9 [33.1] <42.9> 40.7 [42.9] - + 2 2 * Other dimensions are the same as those of the grommet type. 6 3-Port Solenoid Valve/V100 Series Manifold Specifications Manifold Specifications Type S41 Model Manifold Single base type/B mount P (SUP)/R (EXH) type Common SUP/Common EXH Valve stations 2 to 20 stations Output port porting specifications Large flow type (Type U) Port size Standard type / Large flow type (Type A) Location Base Direction Side Type VV100-S41 Port 1, 2, 3 Type Port 1, 3 1/8 VV100U-S41 Port 2 M5 x 0.8 M5 x 0.8 ∗ The V114(A) and the V124(A) cannot be mounted to the same manifold. ∗ For the V124(A), pressure from port 3 and exhaust from port 1. Flow Rate Characteristics∗1 Port size Manifold Type VV100-S41 Type VV100U-S41 Flow rate characteristics 1 → 2 [3 → 2∗1] Port 1, 2, 3 V114 V114A V124 V124A M5 x 0.8 V114UT 1, 3: 1/8 2: M5 x 0.8 C [dm3/(s·bar)] b 0.032 0.13 0.070 0.050 2 → 3 [2 → 1∗1] Cv C [dm3/(s·bar)] b Cv 0.007 0.050 0.26 0.012 0.10 0.016 0.085 0.16 0.020 0.26 0.012 0.032 0.13 0.007 0.085 0.16 0.020 0.070 0.10 0.016 0.14 0.12 0.034 0.15 0.26 0.036 ∗ Values when mounted on the manifold base (5 stations) ∗1 For the V124(A) How to Order Valve Manifold Assembly (Example) Ordering example Us Valve (N.C.) ide Sta V114-5GZ tion s… … 5 4 3 2 1 Ds ide 3 1 2 2 Manifold base (5 stations) VV100-S41-05-M5 Blanking plate assembly V100-77-1A VV100-S41-05-M5 1 set (Type S41, 5 station manifold base part no.) ∗V100-77-1A 1 set (Blanking plate assembly part no.) ∗V114-5GZ 4 sets (Valve) The asterisk denotes the symbol for the assembly. Prefix it to the part nos. of the solenoid valve, etc. Beneath the manifold base part number, enter the valve and option part numbers to be mounted. 7 3-Port Solenoid Valve V100 Series Common SUP/Common EXH Type S41 How to Order For VV100-S41 Standard type / Large flow type (Type A) VV100 S41 1 Stations Port 2 size 02 2 stations M5 … M5 x 0.8 Applicable blanking plate assembly V100-77-1A 20 20 stations 3 2 Port 1 M5 x 0.8 Port 3 M5 x 0.8 Port 2 M5 x 0.8 For VV100U-S41 *1 The V114(A) and the V124(A) cannot be mounted to the same manifold. * For 2 to 9 stations, the port 1 [for the V114(A)] or port 3 [for the V124(A)] entry is only available on the U side (a plug is mounted on the D side). For 10 to 20 stations, it is available on both sides (with no plug mounted). Large flow type (Type U) VV100U S41 05 D Applicable solenoid valve V114UT-5mZ 01 Applicable blanking plate assembly V100-77-1A Stations 1 2 stations … Port 1/3 size 20 20 stations 3 Port 2 M5 x 0.8 02 … 2 2 Applicable solenoid valve*1 V114-mmmm V114A-mmmm V124-mmmm V124A-mmmm M5 … 2 05 Nil F N Port 1 entry U side*2 U D side*2 D Port 1 1/8 Port 3 1/8 B Rc1/8 G1/8 NPT1/8 Both sides *2 Plugs are mounted on the opposite side of the selected ports. Gasket Assembly Blanking Plate Assembly Part No.: V100-31-1A Part No.: V100-77-1A Round head combination screw Have the notch mark on the blanking plate face the port 2 side when assembling. Round head combination screw Notch mark Gasket Blanking plate Gasket Applicable base · Sub-plate · Type VV100(U)-S41 manifold base Applicable base · Sub-plate · Type VV100(U)-S41 manifold base Caution Mounting screw tightening torque M2: 0.12 N·m 8 V100 Series ∗ [ ]: AC < >: Values for the large flow type (Type A) Type S41 Manifold: Side Ported/VV100-S41- Stations -M5 Grommet (G), (H) (Pitch) P = 10.5 5 10 1 - + - + - + L2 2 x ø3.5 (Mounting hole) 25 11.6 5 D side 3 - + 3 - + 21.5 11.5 1 27 [34] <30.9> U side 3 M5 x 0.8 (Port 1, 3) 1 G: Approx. 300 H: Approx. 600 L1 32.4 [34.6] <34.6> (Lead wire length) (Light/surge voltage suppressor) (n station) (1 station) 2 7.7 13 2 (Pitch) P = 10.5 M5 x 0.8 (Port 2) 10.5 L plug connector (L) M plug connector (M) <42> 38.1 [45.1] 11.6 32.5 [34.7] <34.7> 42.3 [44.5] <44.5> 27.5 * Other dimensions are the same as those of the grommet type. Station 2 stations 33.5 L1 27.5 L2 9 * Other dimensions are the same as those of the grommet type. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations 44 38 54.5 48.5 65 59 75.5 69.5 86 80 96.5 90.5 107 101 117.5 111.5 128 122 138.5 132.5 149 143 159.5 153.5 170 164 180.5 174.5 191 185 201.5 195.5 212 206 222.5 216.5 V100 Series 3-Port Solenoid Valve Type S41 Manifold: Side Ported/VV100U-S41- Stations -01m L plug connector (L) (Pitch) P = 10.5 13.2 7 D side 3 32 14 1 29 3 36 1 16.7 7 U side L2 2 x ø3.5 (Mounting hole) 1/8 (Port 1, 3) 4.2 L1 47 (Light/surge voltage suppressor) M plug connector (M) 2 10 15.5 47 37.2 2 (Pitch) P = 10.5 14.7 30 * Other dimensions are the same as those of the L plug connector type. Station 2 stations 36.9 L1 28.5 L2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations 47.4 39 57.9 49.5 68.4 60 78.9 70.5 89.4 81 99.9 91.5 110.4 102 120.9 112.5 131.4 123 141.9 133.5 152.4 144 162.9 154.5 173.4 165 183.9 175.5 194.4 186 204.9 196.5 215.4 207 225.9 217.5 10 V100 Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com Manual Override Operation Warning How to Use Plug Connector Caution Since connected equipment will be actuated when the manual override is operated, first confirm that conditions are safe. M Non-locking push type M Locking slotted type [Standard] [Type B] Press in the direction of the arrow. Turn in the direction of the arrow. 3. Lead wires with sockets attachment/detachment ¡Attachment Insert the sockets into the square holes of the connector (with + , and − indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in, their hooks open, and they are locked automatically.) Next, confirm that they are locked by pulling lightly on the lead wires. ¡Detachment To detach a socket from a connector, pull out the lead wire while pressing the socket’s hook with a stick having a thin tip (approx. 1 mm). If the socket is used again, spread the hook outward. When operating with a screwdriver, turn it gently using a watchmakers’ screwdriver. [Torque: Less than 0.1 N·m] Caution 1. Connector attachment/detachment ¡To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever’s pawl is pushed into the groove and locks. ¡To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out. Cover Groove Pin Lever DC polarity indication -+ Socket Part no. DXT170-71-1 Lead wire Connector Hook 2. Crimping of lead wires and sockets Peel 3.2 to 3.7 mm of the tip of the lead wire, enter the core wires neatly into a socket and crimp it with a special crimp tool. Be careful so that the cover of the lead wire does not enter into the crimping part. Use special tool when crimping. (Please contact SMC for the dedicated crimping tools.) Core wire crimping area Crimping area Core wire Socket Lead wire 0.2 to 0.33 mm2 Max. cover diameter: ø1.7 mm Hook 11 Insulation Lead wire Hook How to Use Plug Connector Cover Groove Pin Connector Socket Caution Plug Connector Lead Wire Length Plug connector lead wires have a standard length of 300 mm, however, the following lengths are also available. Connector Assembly Part Nos. For DC: SY100 30 4A For 100 VAC: SY100 30 1A For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A Without lead wire: SY100 30 A (with connector and 2 sockets) How to Order Include the connector assembly part number together with the part number for the plug connector’s solenoid valve without connector. <Example> Lead wire length 2000 mm For DC For AC V114-5LO SY100-30-4A-20 V114A-1LO SY100-30-1A-20 Lead wire length Nil 6 10 15 20 25 30 50 SMC’s Lead Wire Specifications Cover diameter: 1.55 mm Conductor area: 0.3 mm2 (AWG22 equivalent) 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm V100 Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com Surge Voltage Suppressor Operating Principle <For DC> Grommet, L and M Plug Connector M Standard type (with polarity) With surge voltage suppressor (mS) Polarity protection diode Red (+) The electrical circuit as shown in the left figure, allows reduced holding current consumption and measures power saving. Refer to electrical power waveform as shown below. · Please be careful not to reverse the polarity, since a diode to prevent the reversed current is not provided for the model with power-saving circuit (Standard type). 1 <Electric waveform in power-saving, for the V12 4T> ( ): Values of the V114UT Coil Black (−) 24 V With light/surge voltage suppressor (mZ) Red (+) LED Coil Black (−) M Non-polar type With surge voltage suppressor (mR) (+, −) Varistor 0V 0.4 W (3.2 W) 0.1 W (0.35 W) 0W Polarity protection diode Applied voltage Standard model With power-saving circuit 62 ms (23 ms) <For AC> Grommet, L and M Plug Connector With light (mZ) (~) Coil Varistor (−, +) With light/surge voltage suppressor (mU) Coil (~) (+, −) Varistor Caution Coil (−, +) LED · Please connect correctly the lead wires to + (positive) and – (negative) indications on the connector. · For DC voltages other than 12, 24 VDC, incorrect wiring will cause damage to the surge voltage suppressor circuit since a diode to prevent reverse current is not provided. (Wrong polarity will cause trouble.) · When wiring is done at the factory, positive (+) is red and negative (–) is black. For the varistor surge voltage suppressor for DC, please note that the surge voltage will be suppressed on the controller side as there will be residual voltage according to the protective element and rated voltage. Moreover, the residual voltage of the diode is approx. 1 V. M With power-saving circuit Power consumption has been reduced to approx. 1/4 (approx. 1/9 for the large flow type (Type U)) of that of the standard model by eliminating the need for electrical current for holding. (Effective after more than 62 ms (23 ms for the large flow type (Type U)) energized and 24 VDC rated voltage applied.) i2 LED i1 Timer circuit Black (−) Coil Red (+) Diode Electric circuit (with power-saving circuit) Standard type i1: Inrush current, i2: Holding current Large flow type (Type U) LED Black (−) Diode Red (+) Energy saving IC Polarity protection diode Coil 12 V100 Series Specific Product Precautions 3 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com Connector Assembly with Cover Connector assembly with protective cover enhances dust protection ¡Effective in preventing possible short circuit problems due to contaminants in contact with connector section. ¡Chloroprene rubber for electrical use, which provides outstanding weather resistance and electrical insulation, is used for the cover material. However, be careful not to allow contact with cutting oil, etc. ¡Round cord provides neat appearance. How to Order SY100 - 68 - A Lead wire length (L) Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Connector Assembly with Cover / Dimensions Gray (10) (8) Black (6.9) Red (ø4.1) (8) (40) Connector L (14.5) Connector ¡How to Order Indicate part number of connector assembly with cover in addition to the solenoid valve part number without connector of the plug connector. <Example 1> Lead wire length: 2000 mm V114-5LOZ-M5 SY100-68-A-20 <Example 2> Lead wire length: 300 mm (Standard) V114-5LPZ-M5 Symbol for a connector assembly with cover ∗ No need to indicate the part number for a connector assembly with cover in this case. 13 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations. indicates a hazard with a low level of risk which, Caution: ifCaution not avoided, could result in minor or moderate injury. indicates a hazard with a medium level of risk which, Warning: ifWarning not avoided, could result in death or serious injury. ∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems. ISO 4413: Hydraulic fluid power – General rules relating to systems. IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1: Manipulating industrial robots – Safety. etc. indicates a hazard with a high level of risk which, Danger : Danger if not avoided, will result in death or serious injury. Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/ Compliance Requirements The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”. Read and accept them before using the product. Limited warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.∗2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. ∗2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements 1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. Caution SMC products are not intended for use as instruments for legal metrology. Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country. Revision History Edition B ∗ The AC specification has been changed. Edition C ∗ A large flow type (Type U) has been added. JO ZY Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.