Manual / Guide · 2010
Terminator Salvation 42" Deluxe — Setup and Operations Manual (rev. 7.30.12)
Gun camera and IR sensor tests.
- terminator salvation
- arcade
- camera gun
- infrared
Manual / Guide · 2010
Gun camera and IR sensor tests.
Terminator Salvation™ Setup and Operations Manual 42” Deluxe Revision 7.30.12 Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix™ Inc. All rights reserved. This software is based in part on the work of the Independent JPEG Group. This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. (http://www.openssl.org/) This product includes cryptographic software written by Eric Young ([email protected]) Service Manual Table of Contents Table of Contents Safety ............................................................................................................................................................ 3 Product Specifications................................................................................................................................... 5 Setup ............................................................................................................................................................. 6 Adjustments, Audits and Diagnostics ......................................................................................................... 16 Maintenance (Including critical gun maintenance procdedure) ................................................................ 34 Wiring .......................................................................................................................................................... 37 Parts ............................................................................................................................................................ 42 Troubleshooting .......................................................................................................................................... 50 CoinUp® Operation Overview...................................................................................................................... 56 Forms .......................................................................................................................................................... 65 Page 2 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Safety OPERATION Before operating game, read this manual. Failure to properly install and operate this game could result in malfunction or accident. Operate the game in accordance with the manual. TRANSPORTING The cabinet is very heavy. Because the monitor is high, the cabinet is also very top-heavy. Use appropriate care when moving or transporting cabinet. It contains fragile glass and electronic components. Avoid rough handling. PROXIMITY TO NEON LIGHTS Locating the cabinet near neon lights may reduce the ability of the IR sensors to accurately track the guns. It is recommended that the cabinet be placed far away from neon lights or that any nearby neon lights be turned off. HANDLING COMPONENTS Many components are extremely sensitive to handling, environmental and Electrostatic Discharge (ESD) events— especially the computer. Do not handle it roughly. Before servicing, call your distributor and inquire about the PC warranty. Use proper ESD procedures when servicing. Protect components from harmful environmental conditions, such as extreme temperatures, excessive moisture or other damaging effects. DISCONNECT POWER Always turn the power off and unplug the unit before servicing or making adjustments unless otherwise instructed. Installing or repairing components while power is on can damage the components and void the warranty. GROUNDING Avoid electrical shock. Do not plug in AC power until you have inspected and properly grounded the unit. Only plug into a grounded, three-wire outlet. Do not use a “cheater” plug or cut off the ground pin on the line cord. ELECTRICAL SHOCKS There is no isolation transformer in the cabinet. Disconnect AC power before servicing. However, be aware that lethal voltages can remain in the electronic components even when AC power is disconnected. Use extreme caution when servicing. Verify that there is a working ground connection. If the unit sustains water damage, cease using it immediately and unplug AC power. MONITOR The monitor contains no user serviceable parts. Do not attempt to service the monitor. POWER SELECTOR Before installing game, ensure the voltage on the PC is set properly. There is a 115/230 VAC selector switch that must be set for the correct voltage for your site. Verify the fluorescent lamp rating. The rating must match the line voltage at the installation site. POWER CORD If the power cord is damaged or lost, replace it with an identical cord as supplied by the manufacturer or an authorized service agent. Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 3 Service Manual Safety SURGE SUPRESSOR It is recommended that you plug your game’s power cord into a surge suppressor to help protect from power surges that may damage sensitive electronic components. CONNECTORS Ensure all connectors mate properly. If connectors do not slip in easily, do not force them. Connectors are often keyed and only connect one way. Check for correct orientation. COMPUTER The computer contains sensitive components, including a hard drive. Do not handle it roughly. Call your distributor before servicing its internal components. Ask about warranty information as it relates to the PC. Do not turn the PC power switch on or off. It should remain permanently in the ON position. Cycle AC power on or off with the cabinet power switch. A dongle has been inserted into one of the USB ports. This is required for game play. Do not remove the dongle except for troubleshooting purposes. FLUORESCENT TUBES A dropped fluorescent tube may break and implode. Shattered glass from the implosion can travel long distances and cause bodily injury. Use proper procedures when handling broken materials, as these items can contain hazardous material such as mercury or lead. HAZARD TO EPILEPTICS A small portion of the population has an epileptic condition that may cause seizures. Affected persons experience seizure while watching some television pictures or playing certain video games. People who have not had seizures may still have an undetected epileptic condition. If anyone in your family has experienced epilepsy symptoms (seizures or loss of awareness), consult your physical before using video games. While children play video games, a parent should observe. Be alert to the following symptoms: dizziness, altered vision, eye or muscle twitching, involuntary movements, loss of awareness, disorientation or convulsions. If you or your child experiences these symptoms, discontinue use immediately and consult your physician. MANUAL Keep this manual available and ready for use. If the game fails to function properly, turn off the machine and unplug the AC line cord. Contact your local distributor. Your warranty, when applicable, lasts 60 days from your purchase date. You may not reproduce this document or any of its contents without written authorization from Raw Thrills, Inc. or Play Mechanix™ Inc. SPECIFICATIONS For reasons such as performance, this product’s specifications may change without notice. Federal patent, copyright and other intellectual property laws protect the content, devices and design of the game and its equipment. Page 4 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Product Specifications Electrical Power United States, international and Japan 120 VAC @ 60 Hz, 5 amps 240 VAC @ 50 Hz, 2.5 amps 100 VAC @ 50 Hz, 5 amps DC Power Fuse Guide +5 VDC +12 VDC 3 amp Slow Blow 7 amp Slow Blow Temperature 32° F to 100° F (0° C to 38° C) Humidity Must not exceed 95% relative humidity Dimensions Height: 103.5” (2.63 meters) with Terminator head affixed Width: 47” (1.19 meters) Depth: 63” (1.60 meters) Carton Weight Monitor assembly: 438 lbs. (199 kg) Front pedestal: 192 lbs. (87 kg) Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 5 Service Manual Setup Setup Unpack Materials 1. Place the shipping crates on a flat, stable surface. 2. Cut the banding straps and remove the cardboard lids. 3. Lift off the large cardboard containers surrounding the front pedestal and monitor assemblies and remove any shipping cleats. 4. With at least two people, remove the front pedestal and monitor assemblies from the pallets. 5. Remove any additional banding from the monitor assembly. 6. Set aside the box with the Terminator head. 7. Set aside the box with the side caps. 8. Dispose of any bubble wrap and other packing materials. 9. Remove the coin door key from the coin return chute. 10. Open the top coin door. 11. Locate the key for the back door and the cash box door. 12. Open the cash box door and remove the cash box. 13. Remove the items inside the cash box, including this service manual, an AC line cord, a bag of screws, nuts and tools and a warranty card. 14. With at least one assistant, roll the monitor assembly to a suitable playing area. Note: keep the monitor assembly about eight inches from the wall. PROXIMITY TO NEON LIGHTS Locating the game cabinet near neon lights may reduce the ability of the IR sensors to accurately track the guns. Place the cabinet far away from neon lights or turn off any nearby neon lights. 15. With at least one assistant, roll the front pedestal assembly about a foot in front of the monitor assembly. 16. Remove packing material from the guns. 17. Check the AC line cord for visible signs of damage. Pay particular attention to the plug and line cord insulation. 18. Open the boxes with the Terminator head and side caps and remove all items. 19. Check for shipping damage to the following: Left and right guns, cables and decals Cabinet glass: marquee and monitor Cabinet decals, back door and coin door Terminator head assembly Side caps (two each of two types) Page 6 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Check Electrical Settings 1. 2. 3. 4. Verify the voltage in the nearest AC outlet. Verify the AC outlet ground connection is present and working. Open the back door of the monitor assembly. Near the AC power transformer, verify that the voltage selector switch is set for the correct AC voltage. 5. Route the line cord so that the plug is near the AC outlet. 6. Replace the back door of the monitor assembly. 7. Move the monitor assembly a few inches from the wall. Assemble Terminator Head 1. Using a ladder and an assistant to hold the Terminator head assembly in place, lift the component above rear of monitor assembly. 2. Attach the four-pin connector of the Terminator head assembly into its mate on the rear of the monitor assembly. Note: Do not force connector. If it does not connect easily, turn it 180 degrees and try again. 3. Align bracket of Terminator head assembly with the four holes in the top and on the angled back of monitor assembly. 4. Affix a ¼-20 x 1” black TORX screw and a ¼-20 black flat washer by hand through each of the two top holes. Do not tighten screws. 5. Affix a TORX screw and a flat washer by hand through each of the two holes on the angled part of the bracket into the monitor assembly. 6. Tighten all screws with supplied TORX wrench. Terminator Head Installation Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 7 Service Manual Setup Attach Front Pedestal to Monitor Assembly 1. Move front pedestal assembly a few inches away from the monitor assembly. CONNECTORS Ensure all connectors mate properly. If connectors do not slip in easily, do not force them. Connectors are often keyed and only connect one way. Check for correct orientation. 2. Gently pull all connectors through the round holes in the front pedestal and monitor assembly. 3. Connect single-pin ground cable from monitor assembly to front pedestal. 4. Connect either USB cable from monitor assembly to either USB cable from front pedestal. Note: the USB gun cables are interchangeable. The PC will decide which is the right and left gun. 5. Connect the 10-pin and 16-pin data/power connectors from the monitor assembly to their mates from the front assembly 6. Move front pedestal so that it is flush with monitor assembly. Caution: make sure cables are not pinched. Tuck them back through the round hole into either cabinet. 7. Align holes in monitor assembly brackets with holes in rear of front pedestal assembly. Adjust leg levelers on front pedestal assembly as needed. Monitor Assembly to Front Pedestal Installation 8. Insert a TORX screw and a flat washer by hand through each of the three holes at the front of the left bracket into the three holes of the front pedestal. Do not tighten screws. 9. Repeat with other bracket. 10. Tighten all screws with supplied TORX wrench. Page 8 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Install Side Caps 1. 2. 3. 4. 5. 6. Side Cap Installation (front pedestal unattached to show details) Hold lower left side cap against left side of monitor so that all four holes in side cap align with holes in left side wall of monitor. Note that the lower left and upper right side (Type A) caps are interchangeable. The lower right and upper left side caps (Type B) are interchangeable. Insert a TORX screw, a ¼-20 black lock washer and a flat washer by hand through each of the four holes in side cap into side of monitor. Tighten screws with TORX wrench. Repeat for remaining three side caps. Position game in desired final location. Adjust leg levelers to lift caster wheels above floor and make game level. Note: Use level to check that game is stable and that monitor is parallel to floor. Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 9 Service Manual Setup Startup Game 1. Plug in line cord to AC outlet. 2. Turn the power switch to ON. 3. Verify that the cooling fan located on the bottom back of the game is working. If not, turn off AC power and disconnect line cord. Refer to the diagnostic section of this manual. 4. Check that no component is excessively hot or emitting foul odors. If not, turn off AC power and disconnect line cord. Refer to the diagnostic section of this manual. 5. Once software loads, you will be asked to calibrate the guns. If not, enter the service menu by pressing the TEST button located on the bracket inside the top coin door. Note that gun maintenance procedure is listed on page 34. Page 10 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game First Gun Calibration The Service Button Panel has four buttons, three of which can navigate the menu system. But it is easiest to navigate with a Start button and trigger/ pump. Volume UP TEST SERVICE Volume DOWN Service Panel TEST button enters diagnostic system. Either Start button or TEST button selects the highlighted option. Service Panel VOL - button or Squeezing either trigger moves down through menu or setting choices. Service Panel VOL + button or Pumping either gun moves up through menu or setting choices. Highlight and select Exit to return to previous screen. An on-screen message acknowledges changes or when you exit a selection without making a change. At the bottom of each screen there is a brief description of the menu option’s function. A complete description is available here for all menu functions. Instructions for completing your first calibration start on the next page. Additional gun maintenance procedures are listed on page 34. Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 11 Service Manual Setup 1. If the calibration screen is not already visible, press the TEST button inside the coin door to enter the Diagnostic System. 2. From the Main Menu, use a gun trigger to highlight Gun Calibration. 3. Press a Start button to enter calibration. 4. Pull the trigger on the left gun to indicate that it is Player 1. Please stand directly in front of the cabinet for best results IR GUN CALIBRATION PLEASE PULL THE TRIGGER ON THE LEFT GUN TO VALIDATE THE PLAYER GUN ORDER Press TEST to cancel calibration 5. Stand directly in front of the gun pedestal and aim the left gun at the “+” sign and shoot. Please stand directly in front of the cabinet for best results IR GUN CALIBRATION LEFT GUN SHOOT CENTER TARGET Press TEST to cancel calibration 6. Follow on-screen instructions on the gun tracking screen. The dot indicates the spot where the gun is aimed. Verify accuracy by pointing at different areas of the screen. 7. Accept calibration by pressing the left Start button. Please stand directly in front of the cabinet for best results IR GUN CALIBRATION LEFT GUN TEST CALIBRATION PRESS START TO CONTINUE RELOAD/GRENADE LEFT GUN TO RETRY CALIBRATION Press TEST to cancel calibration 8. Repeat steps 5-7 for right gun. Page 12 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game 9. Press Start button when finished. 10. From Main Menu, squeeze a gun trigger to cycle through choices until you reach System Tests. 11. Press a Start button to select System Tests Menu. MAIN MENU EXIT OPERATOR ADJUSTMENTS GENERAL AUDITS ONLINE MENU GUN CALIBRATION RESET MENU SYSTEM INFORMATION MENU SYSTEM TESTS MENU COLLECTIONS VIEW LOG 12. Squeeze the trigger to highlight the Gun Tests Menu. 13. Press the Start button to select the Gun Camera Test. GUN TESTS EXIT GUN STATUS MESSAGES GUN CAMERA TEST GUN CLICK TEST GUN ELECTRONICS TEST GUN CALIBRATION 14. Press the Start button to return to the System Tests menu. 15. Squeeze the trigger to highlight Gun Camera Test. 16. Press the Start button to begin the test. Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 13 Service Manual Setup 17. You may use one or both guns for this test. Each gun controls a dual-track of colored dots. As you tilt each gun, the orientation of the tracks rotates as the sensors perceive the change in angle. The strength of each gun’s signal is noted in a bar chart. Note whether any of the dots disappear or flicker when near the center of the screen. This may indicate a dirty or poorly functioning camera inside the gun. 18. Press the START button to return to the System Tests menu 19. Squeeze the trigger to highlight the Gun Sensor Test. 20. Press the START button to begin the test. GUN SENSOR TEST IR GUN CALIBRATION POINT EITHER GUN AT THE SCREEN AND AIM ALL AROUND TO ACTIVATE ALL THE SENSORS. ACTIVE SENSORS ARE GREEN. INACTIVE ARE RED. IF A SENSOR NEVER ACTIVATES, THIS MAY INDICATE A PROBLEM WITH THAT SENSOR. PRESS START TO EXIT 21. Sweep the gun from left to right and back again and watch the squares on screen to ensure they all turn green. If any squares remain red as the gun passes them, that particular IR sensor may be dirty or damaged. 22. Press the Start button to return to the System Tests menu. Page 14 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game 23. Squeeze the trigger to highlight the Gun Electronics Test. 24. Press the Start button to begin the test. GUN ELECTRONICS TEST LEFT GUN: FRAMES: 0 LEFT GUN: GLITCHES: 0 LEFT GUN: pBlaze_wd:0 LEFT GUN: pBlaze_pc:0 LEFT GUN: STUCK BITS:0 LEFT GUN: VERSION:0 RIGHT GUN: FRAMES: 0 RIGHT GUN: GLITCHES: 0 RIGHT GUN: pBlaze_wd:0 RIGHT GUN: pBlaze_pc:0 RIGHT GUN: STUCK BITS:0 RIGHT GUN: VERSION:0 25. Ensure the guns pass all tests. 26. Press the Start button to conclude the test and return to the System Tests menu. 27. Press the Start button again to return to the Main Menu. 28. Using the Diagnostic system, described later in this manual, run other diagnostics and make desired adjustments. Other Tests See the Diagnostic Section for further information. 1. 2. 3. 4. 5. 6. 7. Enter the Switch Test menu and verify all switches function. Enter the Screen Test menu and verify that video is acceptable. Enter the Sound Test menu and verify the audio works and is not distorted. Enter the Coin Meter Test menu and verify the operation of the coin meter. Enter the Cabinet Lamps Test menu and verify that all cabinet lights work correctly. Enter the Watchdog Test menu, which reboots the game. Upon a successful reboot, you are ready to make adjustments to pricing, volume and other functions found in the Adjustments, Audits and Diagnostics section. Additional gun maintenance procedures are listed on page 34. Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 15 Service Manual Adjustments, Audits and Diagnostics Adjustments, Audits and Diagnostics Diagnostic Menu Screens and Descriptions See First Gun Calibration for information on accessing the diagnostic menu system. Main Menu MAIN MENU EXIT OPERATOR ADJUSTMENTS GENERAL AUDITS ONLINE MENU GUN CALIBRATION RESET MENU SYSTEM INFORMATION MENU SYSTEM TESTS MENU COLLECTIONS VIEW LOG Main Menu Operator Adjustments Menu This menu controls gameplay, coinage and sound adjustments. OPERATOR ADJUSTMENTS EXIT GAME ADJUSTMENTS COIN ADJUSTMENTS PLAYER COST VOLUME You can improve collections by customizing performance with game adjustments. Each variable on an adjustment menu changes an aspect of game play or appearance. Optimizing these settings can maintain player interest and improve earnings. Monitor the effects of adjustments by comparing audit information and earnings before and after changes. Page 16 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu Operator Adjustments Menu Game Adjustments Menu This controls elements of the player experience and the time the game contacts the CoinUp® server to check for software updates. GAME ADJUSTMENTS EXIT SKILL LEVEL MINIMUM GAME LENGTH EXPERT MODE PROMPT RELOAD OFFSCREEN VIOLENCE SHOOTING MODE TRAINING MODE NORMAL 120 OFF OFF NORMAL DEFAULT OFF Settings, Defaults and Choices Setting Description Default Choices Skill Level Adjusts game difficulty by changing how gun reloads. EASY. Ammunition is restored whenever clip runs out. NORMAL. After each 60 shots, player must reload by pumping gun magazine clip. Normal Normal / Easy Minimum Game Length Adjusts length of game in seconds which adjusts damage amounts. 120 0 - 300 Expert Mode Prompt Disables/Enables access to expert mode of game and the associated leader board. Off Off/On Reload Offscreen Turning this function on allows players to shoot the gun off screen to reload their weapon. This may be useful while you are awaiting a replacement part. Off Off/On Violence Toggles the display of certain violent scenes in the game. Normal Normal / Low Shooting Mode Enables gun sight and tracer bullets for all guns Training Mode Shows extra training videos at start of game Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Default Off Default / Sight Only / Tracer Only / Gun Sight & Tracer Off/On Page 17 Service Manual Adjustments, Audits and Diagnostics Main Menu Operator Adjustments Menu Coin Settings Menu This menu does not set game price, but specifies how much game credit is given for money added to the machine. The smallest accepted coin is a quarter, the typical setting for both coin values in the U.S. The DBV value is also a multiple of 25¢. COIN SETTINGS EXIT FREEPLAY CURRENCY TYPE COIN 1 VALUE COIN 2 VALUE COIN 3 VALUE/DBV PULSE MAXIMUM CREDITS BONUS AWARD UNITS FOR BONUS OFF Dollar $0.25 $0.25 $0.25 $500.00 $0.00 $0.00 Settings, Defaults and Choices Setting Freeplay Currency Type Description Players can start games without money by pressing START. Use this for promotions, non-commercial applications or to test the machine. Changing currency type resets coin door values. The denomination symbol changes on screen with each currency. Default Choices Off On / Off US Dollar Yen, Won, Ruble, Real, Peso, Krona, Guilder, Franc, Can. Dollar, Coins, Euro, NZ Dollar, Rand, Pound, Aus. Dollar Coin 1 Value Lets you set coin slot pricing. $0.25 $0.25 - $63.75 in $.25 increments Coin 2 Value Lets you set coin slot pricing. The bill validator (DBV) translates bills into electronic pulses. Every $1 bill results in four pulses; each $5 bill is 20 pulses; $10 bill is 40 pulses, etc. This setting determines how much game credit is awarded per pulse. With default setting of $0.25, every $1 bill will award $1 in game credit. Set to $0.50, every $1 bill will award $2 in game credit. The highest number of unplayed credits allowed. The amount of credit awarded per bonus unit (see below). $0.25 $0.25 - $63.75 in $.25 increments $0.25 $0.25 - $63.75 in $.25 increments $500 $125 - $500 in $.25 increments $0.00 $0.00 - $63.75 in $.25 increments $0.00 $0.00 - $50.00 in $.25 increments Coin 3 Value / DBV Pulse Maximum Credits Bonus Award Units for Bonus The value a player must enter to get bonus credit. Bonus Award/Units for Bonus example. To give players $1.25 in credit for every dollar put in the DBV, set Bonus award to $.25 and Units for Bonus to $1. Page 18 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu Operator Adjustments Menu Player Cost Menu PLAYER COST TYPE- - - - - - - - - - - - - - -OPER FEE- - - - -COINUP FEE - - - TOTAL EXIT START COST $1.00 $0.00 $1.00 CONTINUE COST $1.00 $0.00 $1.00 Settings, Defaults and Choices Setting Description Default Choices Start Cost The amount of money required to begin a game. $1.00 $0.00 - $63.75 in $0.25 increments Continue Cost The amount of money required for a player to continue a game. $1.00 $0.00 - $63.75 in $0.25 increments FEE ADJUSTMENT Note that CoinUp® fee cannot be adjusted by the operator. Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 19 Service Manual Adjustments, Audits and Diagnostics Main Menu Operator Adjustments Menu Volume Menu Rather than requiring a manual dial or up/down buttons, all volume adjustments can be made digitally with this menu. However, during Attract Mode, pressing the Service Panel Vol + and Vol – buttons only adjusts Attract Mode volume. VOLUME EXIT GAME VOLUME ATTRACT VOLUME MINIMUM VOLUME ATTRACT SOUNDS 9 7 4 OCCASIONALLY Settings, Defaults and Choices Setting Description Game Volume This affects sound only while game is played. Attract Volume Minimum Volume Attract Sounds Page 20 This can be silenced or turned up as an advertisement to draw in players. Determines the lowest setting possible for both Game and Attract Volumes This determines how often the game’s “advertising” sounds will be heard. Default Choices 9 0 – 32 7 0 – 32 4 0 – 32 Occasionally Never/Occasionally/Always Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu Audits Menu Audit screens help assess game performance, find intermittent problems, decide whether to adjust game difficulty and free game award and help maximize game earnings. AUDITS EXIT GENERAL AUDITS SYSTEM AUDITS COIN AUDITS Main Menu Audits Menu General Audits GENERAL AUDITS EXIT PLAYER STARTS PLAYER CONTINUES PLAYER CONTINUES OFFERED GAMES STARTED GAMES ENDED (NOT WON) GAMES COMPLETED (WON) AVERAGE GAME TIME (SHOOTING) AVERAGE GAME TIME (TOTAL) Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC 0 0 0 0 0 0 0 0 Page 21 Service Manual Adjustments, Audits and Diagnostics Main Menu Audits Menu System Audits SYSTEM AUDITS EXIT PLAY TIME UP TIME WATCHDOGS EXCEPTIONS BAD TRAPS 0 yr 0 dy—0:00:00 0 yr 0 dy—0:00:00 0 0 0 Main Menu Audits Menu Coin Audits Menu COIN AUDITS EXIT TOTAL COIN 1 TOTAL COIN 2 TOTAL COIN 3 (DBV) BONUS COINS LIFETIME COIN COUNT SERVICE CREDITS $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Main Menu Online Menu These menus are used by games connected to CoinUp®. See CoinUp® Operation Overview section in this manual and visit www.coinup.com for more information. Page 22 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu Gun Calibration Menu This is the same procedure described earlier in the First Calibration section. Main Menu Reset Menu RESET MENU EXIT RESET GAME AUDITS RESET HIGH SCORES RESET CREDITS RESET COIN COUNTERS RESET ADJUSTMENTS FACTORY RESET Reset Game Audits zeroes out game audits, system audits and game purchase audits. Reset High Scores zeroes out high score tables. Reset Credits zeroes out money in. Reset Coin Counters zeroes out coin audits, but leaves alone lifetime and service credits. Reset Adjustments sets operator adjustments to defaults. Factory Reset performs all the above resets. Main Menu System Information Menu These submenus can give you information on how the system has been functioning and on various settings and updates. SYSTEM INFORMATION EXIT VERSION LIST DIPSWITCH SETTINGS TELEMETRY STATS SWITCH TELEMETRY Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 23 Service Manual Adjustments, Audits and Diagnostics Main Menu System Information Version List For troubleshooting purposes, this menu gives you information on the latest update of various components. VERSIONS EXIT SOUND JAMMA PMNET SOFTWARE LEFT GUN RIGHT GUN 19.3 25q.H8b.Fd1.U2a R 00.00.00 00.84.00.US.D – Build: Dec 8 1009 11:39:04 0 0 Main Menu System Information DIP Switch Settings This checks the DIP Switch settings on the I/O Board DIPSWITCH SETTINGS DIPSWITCH 1 DIPSWITCH 2 DIPSWITCH 3 DIPSWITCH 4 DIPSWITCH 5 DIPSWITCH 6 DIPSWITCH 7 DIPSWITCH 8 ON OFF OFF OFF OFF OFF OFF OFF RESOLUTION RESOLUTION GUN SCAN EtelemeGA HSYNC/VSYNC POLARITY UNUSED UNUSED UNUSED UNUSED PRESS START TO EXIT Page 24 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu System Information Telemetry Stats These tests check thermal qualities and electrical conductivity. Generally, only Core Temps 1 and 2 function. The rest should read N/A. TELEMETRY DATA EXIT SYSTEM TEMPERATURE CORE TEMP1 CORE TEMP2 TEMPERATURE STATE CPU FAN SPEED CASE FAN SPEED +3.3V: +5.0V: +12V: -5.0V: -12.0v N/A 23C 26c N/A N/A N/A N/A N/A N/A N/A N/A Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 25 Service Manual Adjustments, Audits and Diagnostics Main Menu System Information Switch Telemetry Data This gives information on the time since a switch was last used in both number of games played since the switch was used and the clock time since last use. SWITCH TELEMETRY DATA EXIT GAMES NOT SEEN SWITCH 0 LEFT START 0 RIGHT START 0 LEFT TRIGGER 0 LEFT PUMP 0 LEFT GRENADE 0 RIGHT TRIGGER 0 RIGHT PUMP 0 RIGHT GRENADE 0 COIN 1 0 COIN 2 0 DIAG 0 VOLUME UP 0 VOLUME DOWN 0 DBV 0 SERVICE CREDIT 0 TIME LAST SEEN 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 0d00.02.22 Main Menu System Tests Menu These tests check the functioning of peripherals. SYSTEM TESTS EXIT GUN TESTS MENU ONLINE TESTS MENU SWITCH TEST SCREEN TESTS SOUND TEST FILE TEST COIN METER TEST CABINET LAMPS TEST WATCHDOG TEST Page 26 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu System Tests Menu Gun Tests Menu Some gun test descriptions can be found in the First Calibration section earlier in this manual. GUN TESTS EXIT GUN STATUS MESSAGES GUN CAMERA TEST GUN CLICK TEST GUN ELECTRONICS TEST GUN SENSOR TEST GUN CALIBRATION Gun Status Messages displays continually updated status messages, like gun connection and IR array visibility. Gun Camera Test checks IR sensor array visibility. Gun Click Test is shown below. Gun Electronics Test reports the status of the electronic components. Gun Sensor Test confirms that the IR sensor array is functional. Gun Calibration is described elsewhere in this manual. Main Menu System Tests Menu Gun Tests Menu Gun Click Test This tests the various click mechanics of the gun. GUN CLICK TEST GUN #1 CLICK MODE: NO CLICK (PRESS LEFT PLAYER GRENADE BUTTON TO CYCLE MODES) GUN #2 CLICK MODE: NO CLICK (PRESS RIGHT PLAYER GRENADE BUTTON TO CYCLE MODES) Point the gun at the screen for this test. Pressing the grenade button cycles through “NO CLICK,” “SINGLE CLICK ON TRIGGER PULL” and AUTO CLICK ON TRIGGER PULL.” Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 27 Service Manual Adjustments, Audits and Diagnostics Main Menu System Tests Menu Online Tests Menu These tests verify components of the online system. ONLINE TESTS EXIT ETHERNET PORT TEST CARD TEST Main Menu System Tests Menu Online Tests Menu Ethernet Port Test This verifies the functioning of the Ethernet port. Connect loopback adapter and “run test” EXIT RUN TEST Main Menu System Tests Menu Online Tests Menu Card Test If there is a card reader, insert a valid card to reveals the card type (player or operator) and the cardholder’s name. CARD TEST EXIT PLEASE INSERT CARD CARD FOUND: Card Type NAME: Cardholder Name Page 28 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu System Tests Menu Switch Test Menu This checks input switch performance. The activated switch is highlighted on screen. SWITCH TEST COIN1 START 1 VOLUME DOWN TEST TRIGGER1 RELOAD1 GRENADE1 SERVICE COIN2 START 2 VOLUME UP BILL TRIGGER2 RELOAD2 GRENADE2 The Switch Test menu has a unique exit procedure because it checks the switches normally used for navigation. To exit to the main menu, simultaneously press a Start button and squeeze a trigger. Main Menu System Tests Menu Screen Tests Menu SCREEN TESTS EXIT COLOR ADJUSTMENT SCREEN ADJUSTMENT COLOR SCREENS Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 29 Service Manual Adjustments, Audits and Diagnostics Main Menu System Tests Menu Screen Tests Menu Color Adjustment This color bar screen of gray, yellow, cyan, green, magenta, red and blue helps identify missing colors. Missing color bars may indicate bad video RAM in the PC, or a problem with the monitor. Color bars can also help Peak the brightness and black levels Balance red, green and blue drives Check purity problems (color contamination) Compensate for barrel or pincushion distortion Adjust size controls Test for video noise sources (such as bad cables) Page 30 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu System Tests Menu Screen Tests Menu Screen Adjustment Menu This crosshatch screen adjusts width and height, static convergence and purity, brightness and focus. Width and Height Adjust height and width of the crosshatch pattern until the grid fills the screen. Keep all the lines visible, though. If part of the grid goes off the screen, then the game image will, too. Static Convergence and Purity All lines in the crosshatch pattern must be white. Else, there is a convergence or purity problem. Slight color tinges at the extreme edges of the screen are okay. Brightness Ensure the bars are a fairly strong white. Focus Bars with fuzzy edges indicate a focus problem. Adjust the focus control for best sharpness. ADJUST GRID TO FIT SCREEN PRESS START TO EXIT Main Menu System Tests Menu Screen Tests Menu Color Screens These are solid, one-color images that help adjust color drive controls for proper intensity. The screens are black, white, red, green and blue. Press the Start button to cycle through the screens. The white screen helps adjust brightness and color output balance. Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 31 Service Manual Adjustments, Audits and Diagnostics Main Menu System Tests Menu Sound Test Menu This checks sound volume and quality. Missing sounds indicated digital flaws. Distorted sounds suggest analog flaws. Lack of sound suggests disconnected or bad cables or speakers. SOUND TESTS EXIT LEFT CHANNEL RIGHT CHANNEL STREAMING SOUND (STEREO) STREAMING SOUND (STEREO) SOUND FX (STEREO) SOUND FX (STEREO) SPEECH CALL 100 Hz SINE WAVE 1000 Hz SINE WAVE LEFT CHANNEL AND RIGHT CHANNEL play a gunshot on each speaker. The first and second STREAMING SOUND plays a background music track. The first and second SOUND FX plays a sound affect. SPEECH CALL plays a vocal line. 100 and 1000 Hz Sine Waves generate specific frequency sounds. Cancel these sounds by selecting another test. Main Menu System Tests Menu File Tests This tests the integrity of the contents of the hard drive, searching for corrupt or missing game files. Damaged or missing files register as failed and are listed. The only solution to this problem is to restore the system from the DVD-ROM, as described in the Restore the Hard Drive section. Main Menu System Tests Menu Coin Meter Test In this test, the System Tests Menu is the bottom-level menu. Watch the mechanical coin meter, which should increment by one count. If it does, it has passed the test. If it does not, it may not be receiving a pulse from the game. See Troubleshooting for more details. Page 32 Terminator Salvation™ Game Software Copyright © 2010 PlayMechanix ™ Inc. All rights reserved. Terminator Salvation™ 42” Deluxe Game Main Menu System Tests Menu Cabinet Lamps Test This test turns the five different cabinet light lines on and off, cycling through left and right start buttons, the left and right holsters and the T-600 eyes with subwoofer. Main Menu System Tests Menu Watchdog Test This tests the Watchdog circuit, which protects the game against screen freezes (infinite loops). After a countdown, the game resets. To exit before the reset, press either Start or Volume button, squeeze a trigger or pump a gun. If the test succeeds, the game resets normally. If the test fails, the reset process loops or ends abnormally. See the Troubleshooting Chapter to diagnose and correct this problem. If the watchdog is disabled, the countdown will finish with no result. Main Menu Collections COLLECTIONS EXIT SEND COLLECTIONS MESSAGE SHOW COINUP FEE DETAILS LAST COLLECTION DATE GROSS COLLECTIONS COINUP FEES NET COLLECTION NEVER $0.00 $0.00 $0.00 Send Collections Message contacts the server and delivers the latest collections information, zeroing out local coin data. Show Coinup Fee Details shows costs related to advertising, communications and upgrades. Gross Collection is the total amount of money the game has earned since last collection. CoinUp Fees should match total from CoinUp Fee details. Net Collection is Gross minus Fees. Main Menu View Log Menu This lists history of significant events or errors in file system. Terminator Salvation™ Copyright © 2010 T Asset Acquisition Company, LLC Page 33 Service Manual Maintenance Maintenance Regular Gun Maintenance Procedure Terminator Salvation™ is equipped with two state-of-the-art custom-designed gun controllers. In order to maximize income potential, keep the guns in optimal working order by performing the following fivestep procedure every time you empty the cash box. 1. Check the camera lens. Observe the red tinted lens at the tip of the gun to ensure it has no cracks, scratches or di