Guardian Electric TP6x12 DC Push Tubular Solenoid — Datasheet

Read the PDF ↗

Push tubular solenoid, shortlisted for a bore-axis striker.

Author
Guardian Electric
Year
2018
Type
Datasheet
Credit
Guardian Electric; copy hosted by Farnell
  • solenoid
  • tubular
  • push

← Back to the Reference Library

Guardian Electric TP6x12 DC Push Tubular Solenoid — Datasheet

DC Push Tubular Solenoid Model TP6x12 Features: High performance construction Available return spring kit DC applications only See T6x12 for pull applications UL recognized Electrical: Coil Voltages: 6, 12, 24, 48, 110 VDC standard Coil Termination: 6.5” Wire leads 26 AWG (standard) Duty Cycle: 100% Continuous, 25% Intermittent, 10% Intermittent, 1% Pulse Coil treatment: Tape Wrapped Insulation Class: Class A Rating - 105° C (221° F) Dielectric Strength: 1500V 60 Hz Mechanical: Size: 1.54” (L) x .75”(D) Plunger Diameter: 0.093” Plunger Guide Material: Plastic Mounting: Hex Nut Weight: Plunger .4 oz, Total 2.3 oz Life Expectancy: 1 Million Cycles1 1 - Dependent on load conditions Solenoid shown energized with plunger fully seated in extended position Supplied with mounting bracket, hex nut and lock washer shipped loose Standard Part Numbers Model Part Number Duty Cycle Voltage Resistance2 (Ω) Power (W) Current TP6x12-C-12 A420-066091-00 Cont. 12VDC 31.7 4.8 379 mA TP6x12-I-12 A420-066092-00 Inter. 12VDC 12.1 12.5 992 mA TP6x12-C-24 A420-066093-00 Cont. 24VDC 121 5 198 mA TP6x12-I-24 A420-066094-00 Inter. 24VDC 60.6 10.1 399 mA Available Customization: • • • • • Plunger Lead and Connector DC Voltage Duty Cycle Insulation systems up to class H 180° C (356° F) * Minimum quantities apply 2 - Coil resistance tolerance +/- 5% Contact us for custom voltages or duty cycles Typical Push Force Ounces [N] @ 20°C (68°F) Stroke (in.) 0.050 0.125 0.250 0.375 0.500 0.625 HOLDING FORCE Ounces [N] Continuous 100% 13 [3.6] 7 [1.9] 4 [1.1] 2 [0.6] N/A N/A 38 [10.6] 5 Intermittent 25% 19 [5.3] 10 [2.8] 7 [1.9] 5 [1.4] N/A N/A 43 [12] 11 Intermittent 10% 35 [9.7] 23.5 [6.5] 16 [4.4] 12 [3.3] 9.5 [2.6] 4.5 [1.3] 104 [28.9] 37.2 Pulse 1%3 45 [12.5] 34 [9.5] 25 [7] 18 [5] 13 [3.6] 10 [2.8] N/A 69.4 (Distance from fully extended position) 3 Continuous Duty 100% = 100% On Time Intermittent Duty 25% = 25% On Time (100 Seconds On Max Followed By 300 Seconds Off ) Intermittent Duty 10% = 90% On Time (10 Seconds On Max Followed By 90 Seconds Off ) Pulse Duty 1% = 99% On Time (1 Second On Max Followed By 99 Seconds Off ) 3 - Calculated force values to be verified in application GUARDIAN-ELECTRIC.COM 1425 Lake Ave - Woodstock IL 60098 - Phone: 800-762-0369 The information is subject to change without notice. © Guardian Electric Power (W) Optional Return Spring Kit A490-367460-13