Guardian Electric T4x12 DC Tubular Solenoid — Datasheet

DC Tubular Solenoid Model T4x12 Features: High performance construction Available return spring kit DC solenoid applications only See TP4x12 for push application UL recognized Electrical: Coil Voltages: 6, 12, 24, 48, 110 VDC standard Coil Termination: 6.5” Wire leads 26 AWG (standard) Duty Cycle: 100% Continuous, 25% Intermittent, 10% Intermittent, 1% Pulse Coil treatment: Tape Wrapped Insulation Class: Class A Rating - 105°C (221°F) Dielectric Strength: 1500V 60 Hz Mechanical: Size: 1.5” (L) x 0.5”(D) Plunger Diameter: 0.187 Plunger Guide Material: Plastic Mounting: Hex Nut Weight: Plunger 0.3 oz, Total 1 oz Life Expectancy: 1 Million Cycles1 1 - Dependent on load conditions Solenoid shown energized with plunger fully seated Supplied with mounting bracket, hex nut and lock washer shipped loose Standard Part Numbers Model Part Number Duty Cycle Voltage Resistance2 (Ω) Power (W) Current T4X12-C-12D A420-066011-00 Cont. 12VDC 49.8 3 241 mA Available Customization: • • • • • Plunger Lead and Connector DC Voltage Duty Cycle Insulation systems up to class H 180° C (356° F) T4X12-I-12D A420-066012-00 Inter. 12VDC 24.7 6.1 486 mA T4X12-C-24D A420-066013-00 Cont. 24VDC 195 3.1 123 mA T4X12-I-24D A420-066014-00 Inter. 24VDC 96.7 6.3 248 mA Power (W) Optional Return Spring Kit A490-367460-06 * Minimum quantities apply 2 - Coil resistance tolerance +/- 5% Contact us for custom voltages or duty cycles Typical Pull Force Ounces [N] @ 20°C (68°F) Stroke (in.) 0.050 0.125 0.250 0.375 0.500 0.625 HOLDING FORCE Ounces [N] Continuous 100% 4 [1.1] 2 [0.6] 1 [0.3] N/A N/A N/A 22 [6.1] 3 Intermittent 25% 7 [1.9] 3 [0.8] 1 [0.3] N/A N/A N/A 25 [7] 6.2 Intermittent 10% 12.5 [3.5] 7.5 [2.1] 5 [1.4] 3.5 [1] 1.5 [0.4] N/A 43 [12] 22.5 Pulse 1%3 18.5 [5.1] 12.5 [3.5] 8.5 [2.4] 6 [1.7] 3.5 [1] 1.5 [0.4] N/A 70 (Distance from fully seated position) 3 Continuous Duty 100% = 100% On Time Intermittent Duty 25% = 25% On Time (100 Sec On Max 300 Sec off ) Intermittent Duty 10% = 90% On Time (10 Sec On Max 90 Sec off ) Pulse Duty 1% = 99% On Time (1 Sec On Max 99 Sec off ) 3 - Calculated force values to be verified in application GUARDIAN-ELECTRIC.COM 1425 Lake Ave - Woodstock IL 60098 - Phone: 800-762-0369 The information is subject to change without notice. © Guardian Electric