Guardian Electric T12x13 DC Tubular Solenoid — Datasheet

Read the PDF ↗

Pull tubular solenoid: force table at four duty levels, coil table, masses and life.

Author
Guardian Electric
Year
2018
Type
Datasheet
Credit
Guardian Electric; copy hosted by Farnell
  • solenoid
  • tubular
  • pull

← Back to the Reference Library

Guardian Electric T12x13 DC Tubular Solenoid — Datasheet

DC Tubular Solenoid Model T12x13 Features: High performance construction Available return spring kit DC solenoid applications only See TP12x13 for push application UL recognized Electrical: Coil Voltages: 6, 12, 24, 48, 110 VDC standard Coil Termination: 6.5” Wire leads 22 AWG (standard) Duty Cycle: 100% Continuous, 25% Intermittent, 10% Intermittent, 1% Pulse Coil treatment: Tape Wrapped Insulation Class: Class A Rating - 105°C (221°F) Dielectric Strength: 1500V 60 Hz Mechanical: Size: 1.63” (L) x 1.5”(D) Plunger Diameter: 0.5 Plunger Guide Material: Plastic Mounting: Hex Nut Weight: Plunger 1.7 oz, Total 10.2 oz Life Expectancy: 1 Million Cycles1 1 - Dependent on load conditions Solenoid shown energized with plunger fully seated Supplied with mounting bracket, hex nut and lock washer shipped loose Standard Part Numbers Model Part Number Duty Cycle Voltage Resistance2 (Ω) Power (W) Current (mA) T12x13-C-12D A420-066051-00 Cont. 12VDC 22.8 6.6 526 mA T12x13-I-12D A420-066052-00 Inter. 12VDC 7.3 20.7 1.64 A T12x13-C-24D A420-066053-00 Cont. 24VDC 90.4 6.7 265 mA T12x13-I-24D A420-066054-00 Inter. 24VDC 28.4 21.3 845 mA Available Customization: • • • • • Plunger Lead and Connector DC Voltage Duty Cycle Insulation systems up to class H 180° C (356° F) * Minimum quantities apply 2 - Coil resistance tolerance +/- 5% Contact us for custom voltages or duty cycles Typical Pull Force Ounces [N] @ 20°C (68°F) Stroke (in.) 0.050 0.125 0.250 0.375 0.500 0.625 0.750 HOLDING FORCE Ounces [N] Continuous 100% 80 [22.2] 40 [11.1] 18 [5] 10 [2.8] 5 [1.4] 2 [0.6] 1 [0.3] 188 [52.3] 6.7 Intermittent 25% 140 [38.9] 104 [28.9] 55 [15.3] 30 [8.3] 20 [5.6] 15 [4.2] 7 [1.9] 215 [59.8] 21 Intermittent 10% 220 [61.2] 184 [51.2] 145 [40.3] 121 [33.6] 102 [28.4] 89 [24.7] 73 [20.3] 546 [151.8] 62 Pulse 1%3 252 [70.1] 218 [60.6] 180 [50] 154 [42.8] 137 [38.1] 125 [34.8] 108 [30] N/A 198 (Distance from fully seated position) 3 Continuous Duty 100% = 100% On Time Intermittent Duty 25% = 25% On Time (100 Sec On Max 300 Sec off ) Intermittent Duty 10% = 90% On Time (10 Sec On Max 90 Sec off ) Pulse Duty 1% = 99% On Time (1 Sec On Max 99 Sec off ) 3 - Calculated force values to be verified in application GUARDIAN-ELECTRIC.COM 1425 Lake Ave - Woodstock IL 60098 - Phone: 800-762-0369 The information is subject to change without notice. © Guardian Electric Power (W) Optional Return Spring Kit A490-367460-01