Firearms

Reference / Paper · 2012

Frequency-Dependence of Psychophysical and Physiological Responses to Hand-Transmitted Vibration

Read the PDF ↗

Open-access review: hand sensitivity peaks around 80–160 Hz and follows velocity; the basis for choosing rumble frequency.

Author
Michael J. Griffin (Industrial Health 50:354–369)
Year
2012
Type
Reference / Paper
Credit
Industrial Health / JNIOSH (jniosh.johas.go.jp), open access
  • vibration
  • hand-arm
  • psychophysics
  • perception

← Back to the Reference Library

Frequency-Dependence of Psychophysical and Physiological Responses to Hand-Transmitted Vibration

Review Article Industrial Health 2012, 50, 354–369 Frequency-dependence of Psychophysical and Physiological Responses to Hand-transmitted Vibration Michael J. GRIFFIN1 1 Human Factors Research Unit, Institute of Sound and Vibration Research, University of Southampton, United Kingdom Received August 18, 2011 and accepted August 2, 2012 Abstract: This invited paper reviews experimental studies of the frequency-dependence of absolute thresholds for the perception of vibration, equivalent comfort contours, temporary changes in sensation caused by vibration, and reductions in finger blood flow caused by hand-transmitted vibration. Absolute thresholds depend on the contact conditions but for a typical hand grip the thresholds show greatest sensitivity to acceleration around 125 Hz. The frequency-dependence of discomfort caused by hand-transmitted vibration depends on vibration magnitude: similar to absolute thresholds at low magnitudes, but the discomfort at higher magnitudes is similar when the vibration velocity is similar (at frequencies between about 16 and 400 Hz). Hand-transmitted vibration induces temporary elevations in vibrotactile thresholds that reflect the sensory mechanisms excited by the vibration and are therefore highly dependent on the frequency of vibration. Handtransmitted vibration reduces finger blood flow during and after exposure; when the vibration velocity is similar at all frequencies there is more vasoconstriction at frequencies greater than 63 Hz than at lower frequencies. A single frequency weighting cannot provide a good indication of how all effects of hand-transmitted vibration depend on vibration frequency. Furthermore, a single frequency weighting provides only an approximate indication of any single response, because many factors influence the frequency-dependence of responses to hand-transmitted vibration, including the magnitude of vibration, contact conditions, and individual differences. Although the frequency weighting in current standards extends from 8 to 1,000 Hz, frequencies greater than 400 Hz rarely increase the weighted value on tools and there is currently little psychophysical or physiological evidence of their effects. Key words: Vibration, Hand, Perception, Comfort, Vascular, Syndrome, Vibration-induced white finger Introduction Prolonged regular exposure to hand-transmitted vibration results in physiological and pathological disorders among those using a wide variety of vibratory handheld tools in many different occupations. The disorders E-mail: [email protected] ©2012 National Institute of Occupational Safety and Health are complex, moderated by many factors, and may only appear after many years of exposure to vibration. The disorders are associated with exposures to vibration that are also complex (varying in magnitude, frequency, direction, and duration) and vary over time. A recognition of the complexity of the various cause-effect relationships easily leads to the conclusion that they cannot be unravelled, and then expressed quantitatively with any precision, solely by epidemiological studies of those occupationally exposed PSYCHOPHYSICAL AND PHYSIOLOGICAL RESPONSES TO VIBRATION to hand-transmitted vibration. Epidemiological studies mostly assume effects of handtransmitted vibration can be predicted from one measure, or a very small number of alternative measures, of vibration exposure. A measure of vibration severity should take into account the relative importance of different magnitudes of vibration, different frequencies of vibration, different directions of vibration, and different durations of vibration exposure. This may be achieved by assuming ‘weightings’ for different frequencies and directions of vibration and calculating, for example, ‘frequency-weighted’ accelerations in one direction, or a summation of values in three directions (e.g., the root-sums-of-squares, r.s.s.). To take the duration of exposure into account, exposures may be summed over a day (e.g., 8-h equivalent exposures, A(8)), or over a life-time (e.g., years of exposure). Depending on the assumed weightings and methods of summation, many different measures of exposure severity can be obtained and their relationships to observed disorders can be investigated in epidemiological studies. Such studies are required to test relationships, but the multiplicity of co-varying independent variables with poorly-understood roles renders epidemiological studies insufficient to develop the measure of vibration severity to be used in a dose-response relationship. Some weightings (e.g., for frequency, direction, and duration) and some methods of summation (e.g., over frequency, direction, and duration) can be investigated experimentally with humans, especially in studies of short-term subjective and physiological responses to vibration. Studies that do not damage the participants will not directly establish what vibration is required to cause damage. However, such studies can contribute candidate methods for quantifying vibration severity and, most usefully, an understanding of some of the underlying responses to vibration, leading to models of the mechanisms associated with the damage caused by occupational exposures to hand-transmitted vibration. This invited paper seeks to summarise the understanding that is emerging from studies of how psychophysical and physiological responses to hand-transmitted vibration depend on the frequency of vibration. The paper was prepared to assist discussions of alternative frequency weightings during the 12th International Conference on Hand Arm Vibration in Ottawa in June 2011. Of the studies that have systematically explored the influence of the frequency of vibration, the paper focuses on results from comparable conditions that provide a coherent, although incomplete, picture of the nature of, and reasons for, some of the psychophysical and physiological responses to hand-transmitted vibra- 355 tion. For these studies to provide a foundation on which to build a method of predicting the risks of any one of the occupational disorders caused by hand-transmitted vibration it is necessary to establish, or assume, a relation between the psychophysical or physiological responses and the occupational disorder. Irrespective of occupational injuries, improved understanding of psychophysical and physiological responses to vibration has some immediately apparent practical benefits (e.g., optimising vibration perception and minimising vibration discomfort) and may have other unpredictable benefits that arise from a better understanding of how the human body responds to vibration. Subjective Responses to Vibration A subjective response may indicate whether vibration can or cannot be felt. If vibration is felt, a subjective response can indicate the severity of the sensation, the type of sensation, and the location of the sensation. Thresholds for perceiving vibration Mechanisms for perceiving vibration Various physiological mechanisms mediate the perception of vibration. Understanding of tactile perception comes from anatomical, neurophysiological, and psychophysical studies. The differing disciplines have resulted in differing terminologies for referring to the different systems. The skin of the palm of the hand has mechanoreceptors with distinct properties classified as having fast or slow adaptation (FA or SA), and small or large receptive fields (type I or type II). Electrophysiological studies have shown that the fast-adapting units, FA I and FA II, have different properties to the slow-adapting units, SA I and SA II1). There is a greater density of FA I and the SA I receptors in the glabrous skin at the distal ends of the fingers, whereas the FA II and the SA II receptors are more evenly distributed. The FA I receptors are associated with Meissner corpuscles, FA II with the Pacinian corpuscles, SA I with Merkel discs, and SA II with the Ruffini endings2). Studies of neural responses from nerve cells in humans and other animals have investigated physiological thresholds of isolated corpuscles to different types of stimuli. The SA units tend to be the most sensitive units at frequencies less than 5 Hz, FA II units are most sensitive in the range 100 to 300 Hz, and FA I units have a relatively flat response in which they may be more sensitive than other units over the range 10 to 20 Hz (Fig. 1; 3)). From psychophysical studies with humans, it gradually became apparent that the perception of vibration was 356 M GRIFFIN Fig. 2. Four-channel psychophysical model showing the threshold frequency response of each channel (redrawn from 4, 5)). Fig. 1. Tuning curves for glabrous skin in the cat (redrawn from 3)). mediated by more than one mechanism and so the concept of ‘psychophysical channels’ emerged. Bolanowski et al. 4) and Gescheider et al. 5) suggested four channels are involved in the perception of vibration at the thenar eminence of the hand: the slow-adapting non-Pacinian III channel is likely to be most sensitive at frequencies less than about 2 Hz, the fast-adapting non-Pacinian I channel may mediate perception at thresholds levels between approximately 2 and 40 Hz, the fast-adapting Pacinian channel often mediates perception at frequencies greater than about 40 Hz, and the slow-adapting non-Pacinian II channel is sensitive in a frequency range similar to the P channel, but has a sensitivity lower than the P channel with most contact conditions (Fig. 2). The response of the Pacinian channel, with absolute thresholds for displacement and acceleration having a U-shaped frequency-dependence and greatest sensitivity in the range 100 to 300 Hz, is often dominant in glabrous skin. Understanding of the channels involved in the perception of vibration in non-glabrous hairy skin is somewhat limited. The terminology remains confusing, but with the following assumed associations: • Meissner corpuscles − Non-Pacinian I (NP I) − Fast Adapting I (FA I) • Pacinian corpuscles − Pacinian (P) − Fast Adapting II (FA II) • Merkel discs − Non-Pacinian III (NP III) − Slow Adapting I (SA I) • Ruffini endings − Non-Pacinian II (NP II) − Slow Adapting II (SA II) The differing properties of the channels can have a large influence on the frequency-dependence of vibration perception. According to the contact area, stimulus duration, skin temperature, vibration magnitude, etc., different receptors or channels may dominate the response, so giving rise to a different frequency-dependence according to the contact area, stimulus duration, skin temperature, vibration magnitude, etc. The dependence of thresholds on these variables is illustrated for experimental studies having broadly comparable conditions in the next sections. Frequency-dependence of thresholds for hand-transmitted vibration Although contact conditions can influence thresholds for the perception of hand-transmitted vibration, different studies have produced broad agreement on the frequencydependence (6); Fig. 3). Effect of vibration direction The transmission of vibration to the hand differs between directions, but absolute thresholds for the perception of hand-transmitted vibration are broadly similar for the three directions of translational vibration (6); Fig. 4). Effects of contact conditions Thresholds for the perception of vibration in the palm of the hand pushing down on a flat surface that vibrates vertically are broadly similar to thresholds when the hand grips a cylindrical handle that vibrates vertically (7); Fig. 5). However, high frequency thresholds are raised (i.e., less sensitivity) and low frequency thresholds are lowered (i.e., increased sensitivity) when the vibration is applied to the skin via a small vibrating contactor surrounded by a rigid surface in contact with the skin. This is because perception Industrial Health 2012, 50, 354–369 PSYCHOPHYSICAL AND PHYSIOLOGICAL RESPONSES TO VIBRATION 357 Fig. 3. Comparison of median absolute thresholds for vibration perception for each of the three axes of translational vibration at the hand (adapted from 6)). Fig. 4. Comparison of median absolute perception thresholds between the three axes of vibration of the hand with the reciprocal of frequency weighting Wh normalised to 0.01 ms−2 r.m.s. (redrawn from 6)). of high frequency vibration is mediated via the Pacinian channel with spatial summation (there is little spatial summation when the vibrating area is small), whereas the presence of the surround increases the ‘gradient’ causing stretching that it is detected at lower frequencies by the NPI (Meissner) channel. The thresholds in Fig. 5 are shown in terms of both the vibration acceleration and the vibration displacement. While the use of acceleration is recommended in various standards associated with hand-transmitted vibration, the findings of some of the original psychophysical and physiological studies were expressed in terms of the displacement. Although the data are the same, the frequencydependence of an acceleration threshold appears very different from the frequency-dependence of the corresponding displacement threshold. Fig. 5. Comparison of median absolute thresholds for (a) acceleration and (b) displacement between: (i) the palm pressing on a flat plate vibrating vertically, (ii) hand grip on a bar vibrating vertically, and (iii) a finger exposed to vibration from a 6-mm diameter contactor within a 10-mm fixed circular surround (redrawn from 7)). The influence of a fixed surround around a small vibrating probe is well established (7); Fig. 6). The surround determines the area of skin excited by vibration, whereas the gap between the vibrating probe and the surround, that determines the ‘gradient’, depends on the diameter of both the probe and the gap. The surround alters the relative sensitivity of the psychophysical channels, so it alters the shapes of threshold contours and the range of frequencies over which the different receptors determine thresholds. 358 Fig. 6. Comparison of median absolute thresholds for acceleration between: (i) the palm pressing on a flat plate vibrating vertically, (ii) hand grip on a bar vibrating vertically, and (iii) a finger exposed to vibration from a 6-mm diameter contactor within a 10-mm fixed circular surround, and (iv) the reciprocal of frequency weighting Wh (adapted from 7)). For example, with a large surface and no surround, the Pacinian channel may determine absolute thresholds at frequencies as low as about 20 Hz. The introduction of a surround has two effects: (i) it reduces the area affected by vibration (reducing sensitivity in the Pacinian channel and raising Pacinian thresholds) and (ii) increasing the gradient (increasing sensitivity in the NPI channel and lowering thresholds). The Pacinian channel may then only determine thresholds at frequencies greater than about 60 Hz. The range of frequencies determined by the different channels, which depends on various factors and will differ between individuals, changes the frequency-dependence of absolute thresholds for the perception of vibration. It is therefore difficult to state precisely either the channels mediating vibration perception or the frequency-dependence of absolute thresholds for the perception of vibration. Effect of temperature Various studies have shown that thresholds depend on skin temperature (e.g.8–10)). The greatest effect seems to be on thresholds mediated by the Pacinian channel (10); Fig. 7). Changes in temperature therefore tend to alter the frequency-dependence of absolute thresholds, with increased sensitivity to higher frequencies with increased skin temperature. Effect of prior exposure to hand-transmitted vibration on perception thresholds Prior exposure to vibration can alter thresholds for the perception of vibration and other stimuli. The changes can M GRIFFIN Fig. 7. Effect of temperature on frequency-dependence of absolute thresholds for the perception of vibration from a 7-mm diameter contactor with a 1.5-mm gap to a 10-mm fixed circular surround (redrawn from 10)). Fig. 8. Temporary shifts in vibrotactile thresholds measured at the fingertip 30-s after 5-min exposure to 20 ms−2 r.m.s. hand-transmitted vibration (mean data from 5 subjects; thresholds measured using a 7-mm diameter probe with a 1.5-mm gap to a 10-mm diameter fixed circular surround). (Redrawn from 10)). be temporary (temporary threshold shifts, TTS) or permanent (permanent threshold shifts, PTS). Temporary changes in vibrotactile thresholds depend on the magnitude, the frequency, and the duration of handtransmitted vibration. The shift in the threshold at any frequency is dependent on the frequency of the handtransmitted vibration: greatest elevation of low frequency thresholds is caused by low frequency vibration, whereas greatest elevation of high frequency thresholds is caused by high frequency vibration (e.g.,10); Fig. 8). It appears that the shifts in thresholds are channel-specific: a vibration that causes greater excitation within a channel tends Industrial Health 2012, 50, 354–369 PSYCHOPHYSICAL AND PHYSIOLOGICAL RESPONSES TO VIBRATION to cause a greater temporary shift in the threshold of that channel. With the 20 ms −2 r.m.s. vibration used in the study shown in Fig. 8, it is likely that all channels were excited, so it is possible that the sensitivity of all four channels was elevated. However, because the P channel was most sensitive at high frequencies and the NPI channel was most sensitive at low frequencies, the data only confirm elevation of these two channels. It can be seen that thresholds at frequencies greater than 63 Hz were mostly affected by frequencies greater than 63 Hz, whereas thresholds at frequencies less than 63 Hz were mostly affected by frequencies less than 63 Hz. Permanent changes in vibrotactile thresholds are used as diagnostic indicators of sensorineural damage caused by occupational exposures to hand-transmitted vibration (e.g.,11)). Commonly, using apparatus that controls the contact conditions, thresholds are measured at two frequencies expected to be mediated by different channels (e.g., 31.5 Hz for NPI channel and 125 Hz for the P channel). The perception of other sensory stimuli is also affected by acute exposures to hand-transmitted vibration, with perceptions of warm and cool sensations receiving most interest. Although changes in temperature perception appear useful as diagnostic indicators of peripheral sensorineural damage (e.g.,12–14)), the changes associated with acute exposure to hand-transmitted vibration are not large15). Vibration discomfort Equivalent comfort contours show how the vibration magnitude must be changed to maintain a similar subjective assessment of the strength of vibration sensations at different frequencies. Frequency-dependence of equivalent comfort contours The work of Miwa16, 17) had a major influence on the definition of the frequency weighting now used worldwide for quantifying the severity of hand-transmitted vibration18–20). With ten subjects, Miwa determined ‘equal sensation’ contours for vertical and horizontal vibration of the hand pressed on a flat horizontal surface. He investigated the frequency range 3 to 300 Hz and concluded that there was no difference in the subjective response to vertical and horizontal vibration. Miwa concluded that his mean contours could be approximated by constant acceleration from 3 to 6 Hz, constant velocity from 6 to 60 Hz, and constant displacement from 60 to 300 Hz (Fig. 9). The Japanese Association of Industrial Health sub- 359 Fig. 9. The ‘tolerance limit’ and ‘unpleasant limit’ determined by Miwa17) compared with the 10-min ‘intolerable’ and 10-min ‘unpleasant’ level defined by the Japanese Association of Industrial Health21), and the conditions expected to result in 10% of persons showing finger blanching after 5.8 yr exposure for 8 h per day according to ISO 5349-1:200123). sequently modified the frequency-dependence reported by Miwa to constant acceleration from 2 to 16 Hz and constant velocity from 16 to 300 Hz 21). This was later further modified within the ISO standards community to constant acceleration from 8 to 16 Hz and constant velocity from 16 Hz to 1000 Hz (Fig. 9). This first appeared as an asymptotic weighting in Draft International Standard 5349:197922). It was subsequently implemented as realisable frequency weighting Wh and appears in current standards (e.g., ISO 5349–1:200123); ISO 8041:200524)). It will be appreciated that although the frequency weighting Wh was stimulated by the work of Miwa it cannot be said to have the same frequency-dependence as his experimental data: he only studied frequencies in the range 3 to 300 Hz, whereas W h extends from approximately 8 to 1000 Hz and, even over the range 3 to 300 Hz, the frequency-dependence is very different (Fig. 9). In the 45 years since the pioneering work of Miwa, other equivalent comfort contours have been developed (e.g. 25–27)) and show that other factors affect the frequency-dependence of the discomfort caused by handtransmitted vibration. Effect of vibration magnitude The frequency-dependence of the equivalent contours developed by Miwa is very different from the frequencydependence of the absolute threshold for the perception of hand-transmitted vibration. Studies of equivalent comfort over a range of vibration magnitudes show that the frequency-dependence changes as the vibration magnitude 360 M GRIFFIN Fig. 10. Equivalent comfort contours for sensation magnitudes from 25 to 200 relative to a sensation magnitude of 100 for a vibration magnitude of 5.0 ms−2 r.m.s. at 50 Hz and median absolute threshold for perception of fore-and-aft, lateral, and vertical vibration from a cylindrical handle. Frequency weightings represented by reciprocal of Wh drawn to coincide with experimental equivalent comfort contours at 16 Hz. (Adapted from 26, 48)). increases above the absolute threshold for perception. For subjects gripping a cylindrical handle, Morioka and Griffin (2006) investigated perception thresholds (in the frequency range 8 to 315 Hz) and the strength of sensation caused by each of the three axes of hand-transmitted vibration (in the frequency range 8 to 400 Hz) at vibration magnitudes from threshold to those associated with discomfort and injury (Fig. 10). In all three axes, acceleration thresholds for the perception of vibration showed a Ushaped frequency-dependence with greatest sensitivity around 80 to 160 Hz. At supra-threshold levels, the frequency-dependence of the equivalent comfort contours in each of the three axes was highly dependent on vibration magnitude. With increasing vibration magnitude, equivalent sensation approximated towards constant velocity, whereas with decreasing magnitudes the sensation became increasingly similar to the absolute perception threshold. The magnitude-dependence of equivalent comfort contours suggests mediation of the perception of vibration by different channels at different vibration magnitudes. The results also imply that no single linear frequency weighting can provide accurate predictions of subjective judgments of discomfort caused by hand-transmitted vibration: the appropriate frequency weighting depends on the magnitude of vibration. There is some evidence that equivalent comfort contours can be influenced by grip force, with increased sensitivity at high frequencies when increasing grip force with low magnitude vibration27). Hand posture can also be expected to have an effect, especially at lower frequencies where the transmission of vibration to the torso can be reduced by bending of the elbow. Acute Vascular Responses to Vibration Regular and prolonged exposures to hand-transmitted vibration in a wide variety of occupations give rise to permanent vascular changes. In the condition known as vibration-induced white finger, ‘attacks’ of finger whiteness may be provoked by exposure to cold: the underlying disorder is caused by exposure to vibration, but an ‘attack’ of finger blanching is most often caused by cold. Vibrationinduced white finger may therefore be characterised by the peripheral circulation showing an abnormal response to cold. Whereas the normal response to cold is a reduction in finger blood flow, those affected by vibration-induced white finger show a cessation of blood flow in all, or part, of a finger during an attack. The mechanisms involved in the regulation of finger blood flow are complex and not fully understood. The pathogenesis of vibration-induced white finger is also not understood. A single exposure to hand-transmitted vibration does not cause vibration-induced white finger, but it is of interest that finger blood flow is reduced during and following any single exposure to hand-transmitted vibration. The extent to which this acute response reflects the mechanisms Industrial Health 2012, 50, 354–369 PSYCHOPHYSICAL AND PHYSIOLOGICAL RESPONSES TO VIBRATION 361 Fig. 11. Finger blood flow before, during, and after 15-minute exposures to static load (contact force 10 N) or vibration with different combinations of frequencies and unweighted acceleration magnitudes but the same frequencyweighted acceleration (5.5 ms−2 r.m.s.) according to ISO 5349-1:2001 (mean values from 10 males) (adapted from 34)). involved in the chronic changes associated with vibrationinduced white finger has yet to be unravelled. However, the acute changes in finger blood flow can be large and they have attracted interest in how they depend on the characteristics of vibration, including the frequency of vibration. Early studies of the effects of the frequency of vibration on acute changes in finger blood flow used vibration stimuli having either the same acceleration or the same displacement at different frequencies28–32). Different responses were generally obtained at different frequencies, suggesting that neither the acceleration nor the displacement would predict the changes, but the conditions did not include vibrations with the same velocity (consistent with the Wh frequency weighting between 16 and 1,000 Hz) or determine the effects of vibration magnitude (allowing the influence of differing weightings to be determined). A series of experimental studies involving collaboration between the Universities of Trieste in Italy and Southampton in the UK has used finger plethysmography to measure changes in finger blood flow during and following exposure to vibration applied to the finger or hand and investigate how vasoconstriction depends on the frequency of vibration33–35), the magnitude of vibration33, 36, 37), the duration of vibration37, 38), intermittent vibration39), and the force applied by the hand or finger35, 40). Related stud- ies have further investigated the effects of the frequency of vibration41), the magnitude of vibration42), temperature43), and individual variability42, 44). The dependence of vibration-induced vasoconstriction on the frequency of vibration is summarised below. Dependence of vibration-induced vasoconstriction on the frequency and magnitude of hand-transmitted vibration Changes in finger blood flow caused by 15-min exposures to hand-transmitted vibration at 16, 31.5, 63, 125 and 250 Hz were investigated using the same vibration velocity at each frequency, so that the frequency-weighted acceleration was always 5.5 ms −2 r.m.s. (when using frequency weighting Wh)34). In the vibrated right finger, vibration at frequencies from 31.5 to 250 Hz provoked greater reductions in FBF than with either 16-Hz vibration or a static load without vibration (Fig. 11). There were also reductions in finger blood flow in a non-vibrated left finger. In fingers on both hands there were reductions in blood flow after cessation of vibration at frequencies from 31.5 to 250 Hz, with greater reductions at higher frequencies. It was concluded that the frequency weighting in current standards tends to overestimate the vasoconstriction associated with acute exposures to vibration at frequencies around 16 Hz (Fig. 12). Various studies have shown that the vasoconstriction 362 M GRIFFIN Fig. 12. Dependence on vibration frequency of the maximum reduction in finger blood flow (expressed as a percentage of pre-exposure values) during, and 45 min after, 15-min exposures to a frequency-weighted acceleration of 5.5 ms−2 r.m.s. (individual data from 10 male subjects) (adapted from 34)). Fig. 13. Median percentage changes in finger blood flow (%FBF) in the exposed right middle finger and the non-exposed left middle finger as vibration increased from 0 to 15 ms−2 r.m.s. (frequency-weighted) at 16, 31.5, 63, 125, 250 Hz (0 to 11 ms−2 r.m.s. at 315 Hz) and during a control condition without vibration over the same 30-min period. Data from 12 male subjects with linear least squares regressions also shown. (Adapted from 41)). during exposure to vibration increases with increases in the magnitude of vibration but has little dependence on the duration of vibration. By progressively increasing the magnitude of vibration from 0 to 15 ms−2 r.m.s. (frequencyweighted) over 30 minutes (0 to 11 ms−2 r.m.s. at 315 Hz), the magnitude-dependence of the vasoconstriction at 16, 31.5, 63, 125, 250, and 315 Hz has been investigated41). In fingers exposed to vibration and in fingers not exposed to vibration, blood flow reduced with increasing vibration magnitude (Fig. 13). At the same frequency-weighted acceleration according to current standards, finger blood flow was dependent on the vibration frequency, with vibration at 125, 250, and 315 Hz causing the greatest reductions in finger blood flow. With vibration at 250 Hz and 315 Hz, frequency-weighted accelerations less than 1.0 ms−2 r.m.s. reduced finger blood flow, whereas greater weighted acceleration magnitudes were required at the lower frequencies. After the cessation of vibration, finger blood flow in exposed and unexposed fingers also depended on the frequency of vibration, with greater vasoconstriction after exposure to the higher frequencies (Fig. 14). Vibration of one hand produced a similar vasoconstriction in fingers on Industrial Health 2012, 50, 354–369 PSYCHOPHYSICAL AND PHYSIOLOGICAL RESPONSES TO VIBRATION 363 Fig. 14. Percentage changes in finger blood flow in the exposed right middle finger and the non-exposed left middle finger associated with: (i) pre-exposure application of force, (ii) post-exposure application of force, (iii) recovery. Medians and inter-quartile ranges from 12 subjects during a control condition and sessions with vibration at 16, 31.5, 63, 125, 250 and 315 Hz. (Adapted from 41)). the exposed and the unexposed hand, suggesting a centrally mediated response. The findings of this study also show that finger blood flow is reduced by vibration magnitudes much lower than those on very many powered hand tools. A relation between vibration-induced reductions in finger blood flow and vibrotactile perception thresholds mediated by the Pacinian channel has been reported42). With 40 subjects (20 male and 20 female) they measured absolute thresholds for the perception of 125-Hz vibration applied by a 6-mm diameter probe (within a 10-mm diameter surround) to the thenar eminence of the right hand and, separately, any changes in finger blood flow when 125-Hz vibration was applied by the same probe at 0.5 and 1.5 ms−2 r.m.s. (unweighted). These magnitudes were chosen because they were expected to be below the thresholds of some subjects but above the thresholds of others. When the vibration magnitude was greater than individual vibration thresholds, changes in finger blood flow were correlated with thresholds (with both 0.5 and 1.5 ms−2 r.m.s. vibration): subjects with lower thresholds showed greater reductions in finger blood flow (Fig. 15). Females had lower vibrotactile thresholds and showed greater vibration-induced reductions in finger blood flow. It was concluded that mechanoreceptors responsible for mediating vibration perception are involved in the vascular response to vibration. Increases in the magnitude of vibration tend to increase vasoconstriction, both during and after exposure to vibra- tion, and in fingers exposed to vibration and in fingers not exposed to vibration. However, the relation between the magnitude of vibration and the vasoconstriction can only be approximated by a linear relation over a restricted range of vibration magnitudes: it seems that vasoconstriction does not occur below some threshold magnitude, and finger blood flow cannot fall below zero. The inevitable non-linearity in the relation between vibration magnitude and finger blood flow means that the dependence of vasoconstriction on the frequency of vibration must depend on the magnitude of vibration. This may be discerned from Fig. 13. Effect of other factors There are no known systematic studies of how the vasoconstriction caused by different frequencies of vibration combine, although such information is needed if a weighting is used to evaluate the severity of vibration containing more than a single frequency. There are no known systematic studies of how finger blood flow depends on the direction of vibration, or how the effects caused by different directions combine. Such information is needed if weightings are to be used to predict the severity of multi-axis vibration. The changes in vasoconstriction induced by acute exposures to hand-transmitted vibration are complex and interact with other factors that can have a large influence on finger blood flow. For example, the absolute reduction 364 M GRIFFIN Fig. 15. Relation between vibrotactile perception thresholds and FBF% in the middle finger of the right (exposed) hand during exposure to 125-Hz vibration at 0.5 ms−2 r.m.s. and 1.5 ms−2 r.m.s. in male and female subjects. Open symbols: subjects with a perception threshold higher than the vibration magnitude of 0.5 ms−2 r.m.s. or 1.5 ms−2 r.m.s.; solid symbols: subjects with a perception threshold lower than the vibration magnitude of 0.5 ms−2 r.m.s. or 1.5 ms−2 r.m.s. (Adapted from 42)). in finger blood flow is greater when the temperature is greater, but the percentage reduction in finger blood flow relative to finger blood flow before vibration exposure is similar43). Those with greater finger blood flow before vibration tend to have greater blood flow during vibration, and those with greater finger blood flow with one temperature tend to have greater blood flow with another temperature43). Vibration cannot be applied to the body without also applying a force, which may itself cause a change of finger blood flow. Modest levels of force applied by a finger can have a large effect on finger blood flow, possibly due to the constriction of local blood vessels35, 40). Similarly, with force applied by the palm of the hand, blood flow may be reduced in fingers on the exposed hand, probably due to compression of parts of the vascular system serving the fingers12). There is some evidence that force may also reduce finger blood flow in the contralateral hand, possibly due to a central sympathetic effect44). There is no evidence indicating whether the potentially large effects of temperature and force have different effects with different frequencies of vibration. However, different types of tool tend to be dominated by different frequencies of vibration, and different types of tool can be associated with different temperatures and different contact forces. A frequency weighting based solely on laboratory studies with controlled temperatures, forces, and other factors, might allow predictions of the percentage changes in finger blood flow caused by vibration, but other factors need to be considered when predicting the absolute finger blood flow that will occur when using a range of tools with a range of finger temperatures, contact forces, metabolic activities, and other factors. Discussion Although many studies have explored human responses to hand-transmitted vibration it is disappointing that so few have systematically explored how the psychophysical and physiological responses depend on the frequency of vibration. With psychophysical and physiological responses also highly dependent on other variables (e.g., the magnitude of vibration and the contact conditions) it is challenging to provide a coherent view of the current state of understanding. It has been necessary to focus on studies where frequency has been an independent variable within experiments, and where the conditions in different studies can be compared, and this has resulted in references to an uncomfortable number of studies with which the author is associated. There is scope for experimental studies to advance understanding of how the frequency of vibration determines psychophysical and physiological responses to hand-transmitted vibration over a wider range of conditions. Knowledge of the extent to which a response varies with the frequency of vibration is insufficient to define a frequency weighting for evaluating the severity of handtransmitted vibration. It must be known whether the weighting is appropriate at all magnitudes (i.e., the ‘linearity’ of the response), and appropriate in all directions, for Industrial Health 2012, 50, 354–369 PSYCHOPHYSICAL AND PHYSIOLOGICAL RESPONSES TO VIBRATION 365 Fig. 16. Comparisons of frequency weighting Wh with the frequency-dependence of equivalent comfort contours determined experimentally when gripping a cylindrical handle at four subjective magnitudes: (a) 50, (b) 100, (c) 200, and (d) 300 (where a sensation magnitude of 100 is equivalent to the discomfort produced by 5.0 ms−2 r.m.s. at 50 Hz): - - - - foreand-aft, _ _ _ _ lateral, and ———— vertical 26). all durations, and for all disorders. It is also necessary to know, or assume, how vibrations of different frequencies (and directions and durations) should be combined. From the experimental studies it may be concluded that there is much that is not known and rather little that is fully understood. Nevertheless, the findings are sufficient to see that psychophysical and physiological responses have characteristic frequency-dependencies that are non-linear − the dependence of a response on the frequency of vibration varies with the magnitude of vibration. It follows that the dependence of the psychophysical and physiological responses to vibration cannot be predicted with accuracy by using any single simple frequency weighting. It is clearly not wise to predict both thresholds for the perception of hand-transmitted vibration and vibration discomfort using the same frequency weighting (Fig. 10). If interest is restricted to a range of vibration magnitudes, useful predictions of the discomfort produced by handtransmitted vibration may be possible using a single frequency weighting. The same frequency weighting might be used for all three directions of translational vibration. For frequency-weighted vibration magnitudes in the ap- proximate range 1.6 to 4.8 ms−2 r.m.s., it might be casually concluded that the frequency weighting Wh is reasonable (Fig. 15). However, the applicability of weighting Wh has not been investigated at frequencies greater than about 400 Hz. At frequencies greater than about 400 Hz, a vibrating handle generates high levels of noise and so subjective assessments of vibration may seem irrelevant. Even over the frequency range 8 to 400 Hz and with magnitudes in the range 1.6 to 4.8 ms−2 r.m.s. (weighted), it seems that weighting Wh may easily be in error by a factor of 2 (Fig. 16). Greater ‘errors’ can be expected if Wh is used over a wider range of frequencies, or over a wider range of magnitudes, or with a range of grips and postures. Investigations of the frequency-dependence of the vasoconstriction caused by hand-transmitted vibration seem to conclude that vibration magnitudes with the same frequency-weighted acceleration do not produce the same vasoc