Firearms

Datasheet · 2024

Analog Devices ADXL1001 / ADXL1002 Low-Noise High-Frequency MEMS Accelerometers — Datasheet (Rev. A)

Read the PDF ↗

Single-axis analogue ±100 g / ±50 g MEMS accelerometers with a DC–11 kHz response; a candidate for measuring solenoid recoil impulses on the bench.

Author
Analog Devices
Year
2024
Type
Datasheet
Credit
Analog Devices (analog.com)
  • accelerometer
  • mems
  • recoil measurement

← Back to the Reference Library

Analog Devices ADXL1001 / ADXL1002 Low-Noise High-Frequency MEMS Accelerometers — Datasheet (Rev. A)

Data Sheet ADXL1001/ADXL1002 Low Noise, High Frequency MEMS Accelerometers FEATURES FUNCTIONAL BLOCK DIAGRAM ► Single in plane axis accelerometer with analog output ► Linear frequency response range from dc to 11 kHz (3 dB point) ► Resonant frequency of 21 kHz ► Ultralow noise density ► 30 µg/√Hz in ±100 g range (ADXL1001) ► 25 µg/√Hz in ±50 g range (ADXL1002) ► Overrange sensing plus dc coupling allows fast recovery time ► Complete electromechanical self-test ► Sensitivity performance ► Sensitivity stability over temperature 5% ► Linearity to ±0.1% of full-scale range ► Cross axis sensitivity ±1% (ZX), ±1% (YX), ► Single-supply operation ► Output voltage ratiometric to supply ► Low power consumption 1.0 mA ► Power saving standby operation mode with fast recovery ► RoHS compliant ► −40°C to +125°C temperature range ► 5 mm × 5 mm × 1.80 mm LFCSP package APPLICATIONS ► Condition monitoring ► Predictive maintenance ► Asset health ► Test and measurement ► Health usage monitoring system (HUMS) Figure 1. GENERAL DESCRIPTION The ADXL1001/ADXL1002 deliver ultralow noise density over an extended frequency range with two full-scale range options, and are optimized for industrial condition monitoring. The ADXL1001 (±100 g) and the ADXL1002 (±50 g) have typical noise densities of 30 µg/√Hz and 25 µg/√Hz, respectively. Both accelerometer devices have stable and repeatable sensitivity, which is immune to external shocks up to 10,000 g. The ADXL1001/ADXL1002 have an integrated full electrostatic self test (ST) function and an overrange (OR) indicator that allow advanced system level features and are useful for embedded applications. With low power and single-supply operation of 3 V to 5.25 V, the ADXL1001/ADXL1002 also enable wireless sensing product design. The ADXL1001/ADXL1002 are available in a 5 mm × 5 mm × 1.80 mm LFCSP package, and are rated for operation over a −40°C to +125°C temperature range. Rev. A DOCUMENT FEEDBACK TECHNICAL SUPPORT Information furnished by Analog Devices is believed to be accurate and reliable "as is". However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. Data Sheet ADXL1001/ADXL1002 TABLE OF CONTENTS Features................................................................ 1 Applications........................................................... 1 Functional Block Diagram......................................1 General Description...............................................1 Specifications........................................................ 3 Absolute Maximum Ratings...................................5 Thermal Resistance........................................... 5 Recommended Soldering Profile........................5 ESD Caution.......................................................5 Pin Configuration and Function Descriptions........ 6 Typical Performance Characteristics..................... 7 Theory of Operation.............................................10 Mechanical Device Operation.......................... 10 Operating Modes..............................................10 Bandwidth.........................................................10 Applications Information...................................... 11 Application Circuit.............................................11 On Demand Self Test....................................... 11 Ratiometric Output Voltage...............................11 Interfacing Analog Output Below 10 KHz......... 12 Interfacing Analog Output Beyond 10 KHz.......12 Overrange........................................................ 13 Mechanical Considerations for Mounting......... 13 Layout and Design Recommendations............ 13 Outline Dimensions............................................. 15 Ordering Guide.................................................15 g Range Options.............................................. 15 Evaluation Boards............................................ 15 REVISION HISTORY 4/2024—Rev. 0 to Rev. A Change to General Description Section...........................................................................................................1 Changes to Figure 3 and Table 5.....................................................................................................................6 Changes to Figure 17 and Figure 20............................................................................................................... 9 Change to Figure 22...................................................................................................................................... 11 Change to Ratiometric Output Voltage Section..............................................................................................11 Changes to Figure 25.................................................................................................................................... 12 3/2017—Revision 0: Initial Version analog.com Rev. A | 2 of 15 Data Sheet ADXL1001/ADXL1002 SPECIFICATIONS TA = 25°C, VDD = 5.0 V, acceleration = 0 g, unless otherwise noted. Table 1. Parameter1 SENSOR Measurement Range Linearity Cross Axis Sensitivity2 SENSITIVITY (RATIOMETRIC TO VDD) Sensitivity Sensitivity Change Due to Temperature3 ZERO g OFFSET (RATIOMETRIC TO VDD) 0 g Output Voltage 0 g Output Range over Temperature4 NOISE Noise Density 1/f Frequency Corner FREQUENCY RESPONSE Sensor Resonant Frequency 5% Bandwidth5 3 dB Bandwidth5 SELF TEST Output Change (Ratiometric to VDD) Input Level High, VIH Low, VIL Input Current OUTPUT AMPLIFIER Short-Circuit Current Output Impedance Maximum Resistive Load Maximum Capacitive Load6 POWER SUPPLY (VDD) Operating Voltage Range Quiescent Supply Current Standby Current Standby Recovery Time (Standby to Measure Mode) Turn On Time7 OPERATING TEMPERATURE RANGE Test Conditions/ Comments ADXL1001 Min Typ ADXL1002 Max Min Typ Max Unit Percentage of full scale ZX cross axis YX cross axis ±100 ±0.1 ±1.0 ±1.0 ±50 ±0.1 ±1.0 ±1.0 g % % % DC TA = −40°C to +125°C 20 ±5 40 ±5 mV/g % −40°C to +125°C VDD/2 5 VDD/2 5 V g 30 0.1 25 0.1 µg/√Hz Hz 21 4.7 21 4.7 kHz kHz 11 11 kHz 545 mV 100 Hz to 10 kHz ST low to ST high 235 275 510 VDD × 0.7 VDD × 0.7 25 25 V V µA 3 <0.1 20 100 22 3 <0.1 20 100 22 mA Ω MΩ pF nF VDD × 0.3 No external resistor With external resistor 3.0 Output settled to 1% of final value 5.0 1.0 225 <50 VDD × 0.3 5.25 1.15 285 3.0 +125 −40 <550 −40 5.0 1.0 225 <50 5.25 1.15 285 <550 1 All minimum and maximum specifications are guaranteed. Typical specifications may not be guaranteed. 2 Cross axis sensitivity is defined as the coupling of excitation along a perpendicular axis onto the measured axis output. +125 V mA µA µs µs °C 3 Includes package hysteresis from 25°C. 4 Difference between maximum and minimum values in temperature range. 5 Specified as frequency range that is within a deviation range relative to dc sensitivity, range is limited by an increase in response due to response gain at the sensor resonant frequency. analog.com Rev. A | 3 of 15 Data Sheet ADXL1001/ADXL1002 SPECIFICATIONS 6 For capacitive loads larger than 100 pF, an external series resistor must be connected (minimum 8 kΩ). The output capacitance must not exceed 22 nF. 7 Measured time difference from the instant VDD reaches half its value to the instant at which the output settles to 1% of its final value. analog.com Rev. A | 4 of 15 Data Sheet ADXL1001/ADXL1002 ABSOLUTE MAXIMUM RATINGS Table 2. Parameter Rating Acceleration (Any Axis, Unpowered) Acceleration (Any Axis, Powered) Drop Test (Concrete Surface) VDD Output Short-Circuit Duration (Any Pin to Common) Temperature Range (Storage) 10,000 g 10,000 g 1.2 m −0.3 V to +5.5 V Indefinite −55°C to +150°C RECOMMENDED SOLDERING PROFILE Figure 2 and Table 4 provide details about the recommended soldering profile. Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability. Figure 2. Recommended Soldering Profile THERMAL RESISTANCE Thermal performance is directly linked to printed circuit board (PCB) design and operating environment. Careful attention to PCB thermal design is required. θJA is the natural convection junction to ambient thermal resistance measured in a one cubic foot sealed enclosure. θJC is the junction to case thermal resistance. Table 3. Package Characteristics Package Type θJA θJC Device Weight CP-32-261 48°C/W 14.1°C/W <0.2 g 1 Thermal impedance simulated values are based on a JEDEC 2S2P thermal test board with nine thermal vias. See JEDEC JESD51. Table 4. Recommended Soldering Profile Condition Profile Feature Sn63/Pb37 Average Ramp Rate (TL to TP) Preheat Minimum Temperature (TSMIN) Maximum Temperature (TSMAX) Time, TSMIN to TSMAX (tS) TSMAX to TL Ramp-Up Rate Time Maintained Above Liquidous (TL) Liquidous Temperature (TL) Time (tL) Peak Temperature (TP) Time Within 5°C of Actual Peak Temperature (tP) Ramp-Down Rate Time 25°C to Peak Temperature (t25°C) 3°C/sec maximum 3°C/sec maximum 100°C 150°C 60 sec to 120 sec Pb-Free 150°C 200°C 60 sec to 180 sec 3°C/sec maximum 3°C/sec maximum 183°C 217°C 60 sec to 150 sec 60 sec to 150 sec 240°C + 0°C/−5°C 260°C + 0°C/−5°C 10 sec to 30 sec 20 sec to 40 sec 6°C/sec maximum 6°C/sec maximum 6 min maximum 8 min maximum ESD CAUTION ESD (electrostatic discharge) sensitive device. Charged devices and circuit boards can discharge without detection. Although this product features patented or proprietary protection circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality. analog.com Rev. A | 5 of 15 Data Sheet ADXL1001/ADXL1002 PIN CONFIGURATION AND FUNCTION DESCRIPTIONS Figure 3. Pin Configuration Table 5. Pin Function Descriptions Pin No. Mnemonic Description 1 to 9, 31, 32 10, 11, 17 to 19, 21 to 26, 29 12 13, 14, 27, 28 15 16 20 NIC DNC VDD VSS STANDBY ST OR 30 33 VOUT EPAD Not Internally Connected. Do Not Connect. Leave unconnected. 3.0 V to 5.25 V Supply Voltage. Supply Ground. Standby mode Input, Active High. Self Test Input, Active High. Overrange Output. This pin instantaneously indicates when the overrange detection circuit identifies significant overrange activity. This pin is not latched. Analog Output Voltage. Exposed Pad. The exposed pad on the bottom of the package must be connected to ground. analog.com Rev. A | 6 of 15 Data Sheet ADXL1001/ADXL1002 TYPICAL PERFORMANCE CHARACTERISTICS Figure 4. Frequency Response of ADXL1001/ADXL1002, High Frequency (>5 kHz) Vibration Response; a Laser Vibrometer Controller Referencing the ADXL1002 Package Used for Accuracy Figure 7. ADXL1001/ADXL1002 Noise Power Spectral Density (Noise PSD) Below 10 Hz Figure 8. ADXL1002 Noise Power Spectral Density (PSD) Figure 5. ADXL1001 Noise Power Spectral Density (PSD) vs. Frequency Figure 9. ADXL1002 Sensitivity vs. Temperature Figure 6. ADXL1001 Sensitivity vs. Temperature analog.com Rev. A | 7 of 15 Data Sheet ADXL1001/ADXL1002 TYPICAL PERFORMANCE CHARACTERISTICS Figure 10. ADXL1001 Normalized Offset vs. temperature Figure 13. ADXL1002 Normalized Offset vs. Temperature Figure 11. ADXL1001/ADXL1002 Standby Current vs. Supply Voltage Figure 14. ADXL1001/ADXL1002 Measure Mode Supply Current vs. Supply Voltage Figure 12. ADXL1001 Sensitivity Histogram at 25°C Figure 15. ADXL1002 Sensitivity Histogram at 25°C analog.com Rev. A | 8 of 15 Data Sheet ADXL1001/ADXL1002 TYPICAL PERFORMANCE CHARACTERISTICS Figure 16. ADXL1001/ADXL1002 Measure Mode Supply Current Histogram at 5V Figure 17. ADXL1001 Sensitivity Nonlinearity vs. Input Acceleration Figure 18. ADXL1001/ADXL1002 Output (Gray Trace) Settling in Standby (Black); Output Voltage Settles to Midrail (2.5 V) in Standby in <30 µs; Effectively Unfiltered (No Low-Pass Filter) Output analog.com Figure 19. ADXL1001/ADXL1002 Standby Current Histogram at 5 V Figure 20. ADXL1002 Sensitivity Nonlinearity vs. Input Acceleration Figure 21. ADXL1001/ADXL1002 0 g Output Population Rev. A | 9 of 15 Data Sheet ADXL1001/ADXL1002 THEORY OF OPERATION The ADXL1001/ADXL1002 are high frequency, low noise single-axis microelectromechanical systems (MEMS) accelerometers that provide an analog output that is proportional to mechanical vibration. The ADXL1001/ADXL1002 have high g ranges of 100 g and 50 g and are suitable for vibration measurements in high bandwidth applications such as vibration analysis systems that monitor and diagnose machine or system health. the differential capacitor, resulting in a sensor output with an amplitude proportional to acceleration. Phase-sensitive demodulation determines the magnitude and polarity of the acceleration. OPERATING MODES The ADXL1001/ADXL1002 have two operating modes: measurement mode and standby mode. Measurement mode provides a continuous analog output for active monitoring. Standby mode is a nonoperational, low power mode. The low noise and high frequency bandwidth allows the measurement of vibration patterns caused by small moving parts, such as internal bearings, and the high g range provides the dynamic range to be used in high vibration environments such as heating, ventilation, and air conditioning (HVAC) and heavy machine equipment. To achieve proper performance, be aware of system noise, mounting, and signal conditioning. Measurement Mode System noise is affected by supply voltage noise. The analog output of the ADXL1001/ADXL1002 is a ratiometric output; therefore, supply voltage modulation affects the output. Use a properly decoupled stable supply voltage to power the ADXL1001/ADXL1002 and to provide a reference voltage for the digitizing system. Standby The output signal is impacted by an overrange stimulus. An overload indicator output feature is provided to indicate a condition that is critical for an intelligent measurement system. For more information about the overrange features, see the Overrange section. Proper mounting is required to ensure full mechanical transfer of vibration to accurately measure the desired vibration rather than vibration of the measurement system, including the sensor. A common technique for high frequency mechanical coupling is to utilize a sensor stud mount system while considering the mechanical interface of fixing the ADXL1001/ADXL1002 in the stud. For lower frequencies (below the full capable bandwidth of the sensor), it is possible to use magnetic or adhesive mounting. Proper mounting technique ensures proper and repeatable results that are not influenced by measurement system mechanical resonances and/or damping at the desired frequency, and represents an efficient and proper mechanical transfer to the system being monitored. Proper application specific signal conditioning is require to achieve optimal results. An understanding of measurement frequency range and managing overload condition is important to achieve accurate results. The electrical output signal of the ADXL1001/ADXL1002 requires some band limiting and proper digitization bandwidth. See the Interfacing Analog Output Below 10 KHz section and the Interfacing Analog Output Beyond 10 KHz section for more information. Measurement mode is the normal operating mode of the ADXL1001/ADXL1002. In this mode, the accelerometer actively measures acceleration along the axis of sensitivity and consumes 1.0 mA (typical) using a 5.0 V supply. Placing the ADXL1001/ADXL1002 in standby mode suspends the measurement with internal reduction of current consumption to 225 µA (typical for 5.0 V supply). The transition time from standby to measurement mode is <50 µs. The transition from standby to measure mode is shown in Figure 18. BANDWIDTH The ADXL1001/ADXL1002 circuitry supports an output signal bandwidth beyond the resonant frequency of the sensor, measuring acceleration over a bandwidth comparable to the resonant frequency of the sensor. The output response is a combination of the sensor response and the output amplifier response. Therefore, external band limiting or filtering is required; see the Interfacing Analog Output Below 10 KHz section and the Interfacing Analog Output Beyond 10 KHz section for more information. When using the ADXL1001/ADXL1002 beyond 10 kHz, consider the nonlinearity due to the resonance frequency of the sensor, the additional noise due to the wideband output of the amplifier, and the discrete frequency spurious tone due to coupling of the internal 200 kHz clock. Aliased interferers in the desired band cannot be removed, and observed performance degrades. A combination of high speed sampling and appropriate band limiting filtering is required for optimal performance. MECHANICAL DEVICE OPERATION The moving component of the sensor is a polysilicon surface-micromachined structure built on top of a silicon wafer. Polysilicon springs suspend the structure over the surface of the wafer and provide a resistance against acceleration forces. Deflection of the structure is measured using differential capacitors that consist of independent fixed plates and plates attached to the moving mass. Acceleration deflects the structure and unbalances analog.com Rev. A | 10 of 15 Data Sheet ADXL1001/ADXL1002 APPLICATIONS INFORMATION APPLICATION CIRCUIT For most applications, a single 1 µF capacitor adequately decouples the accelerometer from noise on the power supply. A band limiting filter at the output provides suppression of out of band noise and signal. A capacitive load between 100 pF and 22 nF is recommended. The self test function can be activated at any point during normal operation by setting the ST pin to VDD. Self test takes approximately 300 µs from the assertion of the ST pin to a result, and acceleration outputs return approximately 300 µs after the release of the ST pin. While performing the self test measurement, do not use the accelerometer output to measure external acceleration. The output amplifier can drive resistive loads up to 2 mA of source current, for example greater than 2.5 kΩ for 5 V operation. If the output is to drive a capacitive load greater than or equal to 100 pF, a series resistor of at least 8 kΩ is required to maintain the amplifier stability. When inactive, the ST and STANDBY pins are forced low. The overrange indicator is an output that can be monitored to identify the status of the system. Figure 23. ADXL1002 Typical Self Test Delta vs. Supply Voltage RATIOMETRIC OUTPUT VOLTAGE The ADXL1001/ADXL1002 are tested and specified at VDD = 5.0 V; however, it can be powered with VDD as low as 3 V or as high as 5.25 V. Some performance parameters change as the supply voltage is varied. Figure 22. ADXL1001/ADXL1002 Application Circuit ON DEMAND SELF TEST A fully integrated electromechanical self test function is designed into the ADXL1001/ADXL1002. This function electrostatically actuates the accelerometer proof mass, resulting in a displacement of the capacitive sense fingers. This displacement is equivalent to the displacement that occurs as a result of external acceleration input. The proof mass displacement is processed by the same signal processing circuitry as a true acceleration output signal, providing complete coverage of both the electrical and mechanical responses of the sensor system. The ADXL1001/ADXL1002 output is ratiometric to the supply voltage VDD; therefore, the output sensitivity (or scale factor) varies proportionally to the supply voltage. At VDD = 5.0 V, the output sensitivity is typically 40 mV/g and 20 mV/g in the ADXL1002 and ADXL1001, respectively. The zero g bias output is ratiometric also and is nominally midscale relative to the supply voltage (VDD/2). The self test feature can be exercised by the user with the following steps: 1. Measure the output voltage. 2. Turn on self test by setting the ST pin to VDD. 3. Measure the output again. 4. Subtract the two readings and compare the result to the expected value from Table 1, while factoring in the response curve due to supply voltage, if necessary, from Figure 23. analog.com Figure 24. ADXL1002 Sensitivity vs. Supply Voltage Rev. A | 11 of 15 Data Sheet ADXL1001/ADXL1002 APPLICATIONS INFORMATION INTERFACING ANALOG OUTPUT BELOW 10 KHZ The ADXL1001/ADXL1002 sense mechanical motion along a single axis and produces a voltage output. The system performance depends on the output response that is a result of mechanical vibration sensed and signal processing of the electrical output. The sensor must be effectively mechanically coupled. Mechanical coupling can be a complex integration of multiple components, typically unique for each application. Consideration must be made for all mechanical interfaces including the mounting of the MEMS to the PCB (location on the PCB as well as solder chemistry), the size of the PCB (both thickness and active surface area), and the mounting of the PCB to the system being monitored (either in a module or directly mounted). In general, the following guidelines for effective mechanical interface must be used to support up to 10 kHz bandwidth: ► Keep the ADXL1001/ADXL1002 near a stable mechanical mounting on the PCB. ► Provide multiple hard mounting points. ► Keep the PCB thick and avoid a large surface area PCB that The ADXL1001/ADXL1002 output amplifier is stable while driving capacitive loads up to 100 pF directly without a series resistor. At loads greater than 100 pF, an 8 kΩ series resistor or greater must be used. See Figure 25 for an example of the interface including components when measuring mechanical vibration from 0 kHz to 5 kHz, using the AD4000 ADC. For a 5 kHz pass band, a single-pole RC filter is acceptable; however, in some applications, use a more aggressive filter and lower sample rate. The following components are recommended to form a two-pole RC filter at the output of the ADXL1001/ADXL1002: R1 = 91 kΩ, C1 = 330 pF, R2 = 0 Ω, and C2 = not required. A minimum ADC sample rate of 16 kHz is recommended to avoid aliasing. See Figure 25 for an example of the interface including components when measuring mechanical vibration from 0 kHz to 10 kHz. The following components are recommended to form a two-pole RC filter at the output of the ADXL1001/ADXL1002: R1 = 16 kΩ, C1 = 300 pF, R2 = 32 kΩ, and C2 = 300 pF. A minimum ADC sample rate of 32 kHz is recommended to avoid aliasing. The two-pole RC filter produces an attenuation of approximately 84 dB at 200 kHz, the internal clock frequency. induces higher magnitude and lower frequency resonances. ► Ensure the mechanical connection is sufficiently stiff to transfer mechanical forces up to the desired frequency. Below 10 kHz, magnetic and adhesive mounting is possible with proper attention. The EVAL-ADXL1001Z and the EVAL-ADXL1002Z evaluation boards can be used as a reference. The ADXL1001/ADXL1002 electrical output supports a bandwidth beyond the resonance of the sensor. The small signal bandwidth of the output amplifier in the ADXL1001/ADXL1002 is 70 kHz. During the digitization process, aliasing, which is the folding of higher frequency noise and signals into the desired band, can occur. To avoid aliasing noise from the amplifier and other internal circuits (for example, coupling of the internal 200 kHz clock), it is recommended that an external filter be implemented at the desired bandwidth and the chosen ADC sampling rate be faster than the amplifier bandwidth. The output amplifier is ratiometric to the supply voltage, and there are two distinct cases regarding digital conversion, as follows: ► The user has an analog-to-digital (ADC) downstream of the accelerometer that can use the VDD voltage as a reference. In this case, the voltage supply tolerance and voltage temperature coefficient (commonly associated with external regulators) tracks between the sensor and the ADC and, therefore, the supply and reference voltage induced error cancels out. This design approach is recommended. ► If the ADC cannot reference the same 5 V supply as the sensor for any reason, the sensitivity of the digitized sensor output reflects the regulator tolerance and temperature coefficient. analog.com Figure 25. Application Circuit for the ADXL1001/ADXL1002 INTERFACING ANALOG OUTPUT BEYOND 10 KHZ The ADXL1001/ADXL1002 are high frequency, single-axis MEMS accelerometer devices that provide an output signal pass band beyond the resonance frequency range of the sensor. Although the output 3 dB frequency response bandwidth is approximately 11 kHz (note that this is a 3 dB response, meaning there is a gain in sensitivity at this frequency), in some cases, it is desirable to observe frequency beyond this range. To accommodate this, the ADXL1001/ADXL1002 output amplifier supports a 70 kHz small signal bandwidth, which is well beyond the resonant frequency of the sensor. Although a mechanical interface is always important to achieve accurate and repeatable results in MEMS applications, it is critical in cases when measuring greater than a few kilohertz. Typically, magnetic and adhesive mounting are not sufficient to maintain Rev. A | 12 of 15 Data Sheet ADXL1001/ADXL1002 APPLICATIONS INFORMATION proper mechanical transfer of vibration through these frequencies. Mechanical system analysis is required for these applications. When using the ADXL1001/ADXL1002 beyond 10 kHz, consider the nonlinearity due to the resonance frequency of the sensor, the additional noise due to the wideband output of the amplifier, and the discrete frequency spurious tone due to coupling of the internal 200 kHz clock. If any of these interferers alias in the desired band, it cannot be removed and observed performance degrades. A combination of high speed sampling and appropriate filtering is required for optimal performance. range). Built in overrange detection circuitry provides an alert to indicate a significant overrange event occurred that is greater than approximately 2× the specified g range. When an overrange is detected, the internal clock is disabled to the sensor for 200 µs to maximize protection of the sensor element during an overrange event. If a sustained overrange event is encountered, the overrange detection circuitry triggers periodically, approximately every 500 µs. The first consideration is the effect of the sensor resonance frequency at 21 kHz. Approaching and above this frequency, the output response to an input stimulus peaks, as shown in Figure 4. At frequencies near or above the resonance, the output response is outside the linear response range and, therefore, the sensitivity is different than observed at lower frequencies. In these frequency ranges, the relative response (as opposed to absolute value) over time is typically observed. The ADXL1001/ADXL1002 output amplifier small signal bandwidth is 70 kHz. The user must properly interface to the device with proper signal filtering to avoid issues with out of band noise aliasing into the desired band. The amplifier frequency response roll off can be modeled as a single-pole, low-pass filter at 70 kHz. In the absence of additional external low-pass filtering, to avoid aliasing of high frequency noise, choose a sampling rate of at least twice the equivalent noise bandwidth (ENBW) for a single-pole, low-pass filter, as follows: ENBW    7 0 kH z  11 0 kH z 2 (1) That is, sampling rate must be at least 220 kHz. This sample rate addresses reducing broadband noise due to the amplifier from folding back (aliasing) in-band, but does not prevent out of band signals from aliasing in-band. To prevent out of band responses, additional external low-pass filtering is required. Figure 26. ADXL1001/ADXL1002 Behavior During a Continuous Overrange MECHANICAL CONSIDERATIONS FOR MOUNTING Mount the ADXL1001/ADXL1002 on the PCB in a location close to a hard mounting point of the PCB. Mounting the ADXL1001/ ADXL1002 at an unsupported PCB location, as shown in Figure 27, may result in large, apparent measurement errors due to undamped PCB vibration. Placing the accelerometer near a hard mounting point ensures that any PCB vibration at the accelerometer is above the mechanical sensor resonant frequency of the accelerometer and, therefore, effectively invisible to the accelerometer. Multiple mounting points, close to the sensor, and a thicker PCB also help to reduce the effect of system resonance on the performance of the sensor. Another issue that must be addressed is the coupling of the internal clock signal at 200 kHz onto the output signal. This clock spur must be filtered by analog or digital filtering so as not to affect the analysis of results. For example, to achieve the lowest rms noise and noise density for extended bandwidth applications, it is recommended to use at least a multiple order low-pass filter at the output of the ADXL1001/ ADXL1002 and a digitization sample rate of at least 4× the desired bandwidth, assuming sufficient filtering of the 200 kHz internal clock signal. Use an ADC sample rate of 1 MSPS or greater along with digital low-pass filtering to achieve similar performance. Figure 27. Incorrectly Placed Accelerometers LAYOUT AND DESIGN RECOMMENDATIONS Figure 28 shows the recommended printed circuit board land pattern. OVERRANGE The ADXL1001/ADXL1002 have an output (OR pin) to signal when an overrange event (acceleration larger than twice the full-scale analog.com Rev. A | 13 of 15 Data Sheet ADXL1001/ADXL1002 APPLICATIONS INFORMATION Figure 28. Recommended Printed Wiring Board Land Pattern analog.com Rev. A | 14 of 15 Data Sheet ADXL1001/ADXL1002 OUTLINE DIMENSIONS Package Drawing (Option) Package Type Package Description CP-32-26 LFCSP 32-Lead, Lead Frame Chip Scale Package For the latest package outline information and land patterns (footprints), go to Package Index. Updated: April 01, 2024 ORDERING GUIDE Model1 Temperature Range Package Description ADXL1001BCPZ ADXL1001BCPZ-RL ADXL1001BCPZ-RL7 ADXL1002BCPZ ADXL1002BCPZ-RL ADXL1002BCPZ-RL7 -40°C to +125°C -40°C to +125°C -40°C to +125°C -40°C to +125°C -40°C to +125°C -40°C to +125°C 32-Lead LFCSP (5mm x 5mm x 1.8mm w/ EP) 32-Lead LFCSP (5mm x 5mm x 1.8mm w/ EP) 32-Lead LFCSP (5mm x 5mm x 1.8mm w/ EP) 32-Lead LFCSP (5mm x 5mm x 1.8mm w/ EP) 32-Lead LFCSP (5mm x 5mm x 1.8mm w/ EP) 32-Lead LFCSP (5mm x 5mm x 1.8mm w/ EP) 1 Packing Quantity Reel, 4000 Reel, 1000 Reel, 4000 Reel, 1000 Package Option CP-32-26 CP-32-26 CP-32-26 CP-32-26 CP-32-26 CP-32-26 Z = RoHS Compliant Part. G RANGE OPTIONS Model1 g Range ADXL1001BCPZ ADXL1001BCPZ-RL ADXL1001BCPZ-RL7 ADXL1002BCPZ ADXL1002BCPZ-RL ADXL1002BCPZ-RL7 ±100 g ±100 g ±100 g ±50 g ±50 g ±50 g 1 Z = RoHS Compliant Part. EVALUATION BOARDS Model1 Description EVAL-ADXL1002Z EVAL-ADXL1001Z ADXL1002 Evaluation Board ADXL1001 Evaluation Board 1 Z = RoHS Compliant Part. ©2017-2024 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. One Analog Way, Wilmington, MA 01887-2356, U.S.A. Rev. A | 15 of 15